92
26.11.07 1 689 979 924N
18.5
Roller set for BT 6xx
Smallest useful axle width
mm
800
Largest useful axle width
mm
2800
Roller diameter
mm
282
Roller length
mm
1100
Center distance of rollers
BT 6xx
mm
475
Driving roll, installed in elevated position mm
50
Roller coating
P SiC
Testable wheel sizes:
smallest 5,20-10"
mm
440
largest 14,00-20"
mm
1400
Functional range
°C
-25 to +55°C
Measuring accuracy in the temperature range
of
°C -10 to +40°C**
** When installed in unprotected rooms, the control cabinet must
be roofed over and a control cabinet heating device (optional
extra) must be installed.
18.6
Weighing device
Load bearing capacity (including roller set)
2 x 20t
Weighing range
2 x 20.000 daN
Resolution
4 daN
Accuracy
2% of measuring value
± 20 daN to 1000 daN
Length of connecting cable
32 m
Operating temperature range
Accuracy
-10°C to +40°C
Funktion
-25°C to +50°C
18.7
Radio pressure sensor
Base station
Interface:
RS232
Baud rate:
19,2 kBit/s
Transmission direction:
bi-directional, full-duplex
Radio pressure sensor
HousingL x W x H:
135x62x15mm
Material:
ABS-plastic
Sensor types for measuring ranges:
Compressed air:
0-20 bars
Compressed air connection:
M16 x 1,5 (internal thread)
Degree of protection (according to DIN 40 050)
IP65
Permissible air humidity (relative, without condensation): up to 99 %
Operating temperature
- 10 to +65 °C
Storage temperature (optimum):
+10 to +30 °C
Accumulators:
3x 700mAh NiMh (no memory effect)
Specifications of radio transmission
Transmitter power:
10 mW
Transmitting frequency:
433-434 MHz
Certification according to CE regulations: certification for the
entire EU (certification in other countries on request)
Range depending on on-site conditions
Max: 180 m
Transmission direction:
Radio, bi-directional, half duplex
Max. loading time after total discharge:
20 h
Max. operating time without reloading:
ca. 15 h
Loading station
Material:
ABS
Loading type:
inductive
Degree of protection (according to DIN 40 050):
IP30
Supply (5 loading stations):
24V DC / 420mA
Entire system
Parallel operation of complete systems:
2 syst ms with 10 radio pressure sensors each
Max. number of radio pressure sensors:
10 for each system
Performance data
Base station
Power supply (plug-in power supply unit):
90-265 V AC
Power supply, receiver:
12V DC
Loading station
Power supply (plug-in power supply unit):
90-265 V AC
Accuracy and resolution of pneumatic sensors
Aluminium diaphragm with wire strain gage (DMS):
Pressure measurement
Max. load:
23 bars
Measuring range:
0-20 bars
Accuracy:
%FS (full scale) 0,5 (typ.)
Measuring value resolution:
0,01 bars
Summary of Contents for BT 610
Page 4: ...4 26 11 07 1 689 979 924N ...
Page 5: ...1 689 979 924N 26 11 07 5 Deutsch ...
Page 49: ...1 689 979 924N 26 11 07 49 English ...
Page 94: ...94 26 11 07 1 689 979 924N ...