background image

NUMATIC - NVD 750F / SNTD 750

NOTE:

    As with all electrical equipment, care and attention must be exercised at all

times during its use, in addition to ensuring that routine and preventative maintenance is
carried out periodically in order to ensure its safe operation.  In particular the electrical
supply cable and flexible hose should be regularly inspected by a competent person
and immediate action taken to rectify any faults found.  Failure to carry out maintenance
as necessary, including replacement of parts to the correct standard, could render the
equipment unsafe and the manufacturer can accept no responsibility in this respect.
See the enclosed exploded drawings for correct replacement parts.

_____________________________________________________

MACHINE COMPONENTS

Powerhead

The 2 bypass vacuum motors are housed within the epoxy coated steel head.  To start
the vacuum, there is 1 switch mounted on the front of the handle assembly.  The
powerhead is removed by lifting up on the 2 steel toggles and releasing the claws from
the rim of the powerhead.

The exhaust port of the vacuum is equipped with a screw on diffuser to divert the
exhaust airflow.  This may be removed if required.  Also it is possible to fit an exhaust
hose to divert the processed vacuum air to another area.  For this it is recommended to
use the shortest 2" Numatic hose possible, and to increase the diameter to proprietary
exhaust hose as soon as possible to reduce back pressure.

Summary of Contents for NVD 750F

Page 1: ...respect See the enclosed exploded drawings for correct replacement parts _____________________________________________________ MACHINE COMPONENTS Powerhead The 2 bypass vacuum motors are housed within the epoxy coated steel head To start the vacuum there is 1 switch mounted on the front of the handle assembly The powerhead is removed by lifting up on the 2 steel toggles and releasing the claws fro...

Page 2: ...Failure to do so will drastically reduce the working life of the HEPA filter As a safety precaution in sensitive areas it is possible to secure the HEPA filter module to the powerhead by using split pins These can be inserted through the holes in the steel retaining toggles once they are closed The HEPA filter is capable of filtration to 99 97 to 0 3 microns even if the intake of the machine is co...

Page 3: ...is This will carry the full weight of the machine and recovered debris The front of the chassis has a horizontal bar with two punched holes in it This is to allow wide area wet or dry cleaning kits to be fitted to the machine The machine body is attached to the chassis with a steel toggle It can be removed from the chassis by lifting up the toggle Accessories The is equipped with our standard inta...

Page 4: ...icative of blocked main filters a blocked HEPA filter or blocked hoses Servicing Any servicing required should be carried out by qualified personnel Do not attempt to clean the microfilter cartridge If it becomes excessively clogged fit a new unit Take care when fitting the new cartridge not to handle or rupture the paper element as this will affect the filtration efficiency of the machine Care sh...