background image

PROGRAMMABLE WALL SWITCH
MODEL TI033 - SINGLE POLE

THE MAXIMUM LOAD MUST NOT EXCEED:

incandescent or halogen lighting, block
heater, etc.

ballast equipped installations as: fluorescent
sodium lamp, etc.

pool filter, fan, etc.

INSTALLATION

WIRING DIAGRAM

1 - Turn off the power at the circuit breaker to avoid an electrical shock.
2 - Remove and disconnect the existing switch.
3 - Connect each wall switch lead to each circuit conductor as shown in above

diagram.

4 - Restore power at circuit breaker.

POWER-ON

1.

Lift up the bottom of the door using a small 
screwdriver.

2.

Be sure that the ON/OFF switch is set to ON.

3.

Press on the « reset » button using a paper
clip.

4.

On the display, 0:00 and MO should flash.

If  there  is  nothing  on  the  screen,  test  the
following points :

a)

Maybe the ON/OFF switch located at lower part of the unit is not properly
engaged in ON position. Push it to the right using a small screwdriver.

b)

If the wall switch controls a lamp equipped with an on/off switch, care must
be taken to keep the lamp switch in ON position.

SETTING TIME AND DAY

Before starting programming, you have to set the hour format (12 hrs. & 24 hrs).

1- You can change the time format anytime from 24 hrs.  to 12 hrs.  and back.

To do so,  keep  the MIN key  pressed down as HOUR key  is pressed and
released. Then, release MIN key.

2- Set the day by using the DAY key (if the current day is Tuesday, press and 

VAC

release  DAY  key  until  TU  indicator  appears  on  the  lower  area  of  the
screen).

3- Set the time by using the HOUR and MIN keys (for the 12 hrs. time format,

if you are setting an afternoon or evening time, make sure that the PM indi-
cator is turned on at left side of the screen).

4- Close the door or press on one of the « control » keys to return to normal

operations.

OPERATING MODES

The wall switch has 2 operating modes: the MANual and AUTOmatic modes.

In the MANual mode, the wall switch is like any normal single pole switch.  By
pressing  on  the  door,  the  user  turns  on  and  turns  off  the  light.  The  display
shows the MAN indicator as well as light state (ON or OFF).

The AUTOmatic mode executes in sequence (hourly) the user’s recorded pro-
grams.  To  place  the  wall  switch  in  this  mode,  press  on  the
door for 3 seconds until AUTO appears on the screen.  The display shows the
active program number and the light state (ON or OFF).

To  override  temporarily  the  programming,  press  on  the  door.  The  overridden
state  indicator  will  flash  to  show  that  this  state  is  temporary.  The  override
remains in effect until overridden again or until the next program is reached. To
return in  manual  mode,  press  on  the  door  for  3  seconds  until  MAN  indicator
appears on display.

RECORDING THE PROGRAMS

The memory of this wall switch can hold up to 7 programs.  Each program con-
sists of a time ON (turn on) and a time OFF (turn off) which can be run for  a
single day or for everyday of the week.

ATTENTION:

Both ON and OFF programming sequences must be recorded.

1 - Open the door of the wall switch using a small screwdriver.

2 - Press on the PGM key.

The display will show the number 1 (program 1) on the lower right corner
and the program state (ON/OFF) on the upper right corner. Note that the
clock is  replaced by  

-- : -- 

showing that the selected program is not acti-

vated. 

3 - Press on the DAY key to select the day to which you want the light to turn

on.

If you want the program to be repeated for each day of the week, keep
pressing on DAY several  times until every  day  of the week  appears on
the screen.

4

Press on the HOUR and MIN keys  to set the time to which you  want  the
light to turn on.

Make sure that PM indicator appears on the screen if you want an after-
noon period (12 hrs.  time format).

5- Press  a  second  time  on  PGM  key  to  set  the  time  for  the  light  to  turn off.

Repeat steps 3 and 4 to set the time.

If the program 1 ON is set for every day of the week, the program 1 OFF
will automatically be set for every day.

6- To enter programs 2 to 7, repeat steps 2 to 5.

If you need only one program, just leave the others inactive.  If you want to
erase a program, select it by using the PGM key and then hold PGM key for
3 seconds. The program will be erased when the display will show

-- : -- .

7- Close the door or press on one of the « control » keys to return to normal

operation.

MEMORY BACKUP

This wall switch is equipped with a rechargeable battery which will protect your
programs during a power failure.

Note that the screen blanks during a power failure.

720-033000 1/2

Resistive

20A

Inductive

20A

Motor

1HP

Under 120 VAC / 60 Hz

Reviews: