C/C++ Library
•
27
C/C++ (Windows 95)
U16 W_6308_Get_DA_Status (U16 cardNo)
Visual Basic (Windows 95)
W_6308_Get_DA_Status (ByVal cardNo As Integer) As
Integer
@ Argument
cardNo:
The card number of PCI-6308 cards
@ Return Code
0 (low): no DA value is sending
1 (high): the DA value is sending
5.9 _6308_DI
@ Description
This function is used to read data from digital input ports. There
are 4 digital input channels on PCI-6308. The retrieved value is
stored in DIData. Note that
@ Syntax
C/C++ (DOS)
U16 _6308_DI (U16 cardNo, U16 *DIData)
C/C++ (Windows 95)
U16 W_6308_DI (U16 cardNo, U16 *DIData)
Visual Basic (Windows 95)
W_6308_DI (ByVal cardNo As Integer, DIData As Integer)
As Integer
@ Argument
cardNo:
the card number of PCI-6308 cards
DIData:
the value read from digital input port
@ Return Code
ERR_NoError
5.10 _6308_DO
@ Description
This function is used to write data to digital output ports. There are
4 digital output channels on PCI-6308, i.e. the output value ranges
from 0 to 15.
@ Syntax
C/C++ (DOS)