NuAire OPUS 40 Installation Manual Download Page 1

1

27. 01. 22. Document Number  671398

Nuaire | Western Industrial Estate | Caerphilly | CF83 1NA | nuaire.co.uk

OPUS(40/60/95)

230V Surface & Recess Mounted  
Domestic Single & Twin Fans 

Installation Manual

1.0 SAFETY INFORMATION

• 

The provision of the electrical supply and the connection of the unit to the electrical supply must 
be carried out by a qualified electrician.

• 

Isolate from power supply before removing any covers. During installation / maintenance ensure 
all covers are fitted before switching on the mains supply. 

• 

All-pole disconnection from the mains as shown in the wiring diagram must be incorporated 
within the fixed wiring and shall have a minimum contact separation of 3mm in accordance with 
latest edition of the wiring regulations.

• 

This unit must be earthed.

• 

Ducting must be securely fixed with screws to the spigot to prevent access to live parts. Duct 
runs terminating close to the fan must be adequately protected by suitable guards.

• 

If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or 
similarly qualified persons in order to avoid a hazard. The replacement cord must be of the same 
technical specification as the original cord or greater.

• 

This appliance should not be used by children or persons with reduced physical, sensory or 
mental capabilities or lack of experience and knowledge, unless they have been given supervision 
or instruction concerning the safe use of the appliance by a person responsible for their safety. 
Children shall not play with the appliance. Cleaning and user maintenance shall not be carried 
out by children.

1.1 Symbols

 

GENERAL WARNING 

 

 

Signifies a general warning regarding hazard specified by supplementary information.

 

ELECTRIC SHOCK

 

 

 

This unit must be completely electrically isolated before any panels are removed. Check  

 

 

mains supply and control connections. 

 

ROTATING PARTS 

 

 

 

This unit contains fast moving rotational parts which may start automatically. It is the  

 

 

sole responsibility of the installer to adequately guard these components.

 

REFER TO INSTRUCTION MANUAL

 

 

 

Read and understand the installation and maintenance manual before installing,    

 

 

operating or maintaining this product.

Summary of Contents for OPUS 40

Page 1: ...be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard The replacement cord must be of the same technical specification as the original cord or gre...

Page 2: ...r environmental air Nuaire would always recommend a site specific risk assessment by a competent person to determine if any additional PPE is required 2 0 INTRODUCTION The Nuaire range of Opus 230V fa...

Page 3: ...nge to inner case screw 3 5 x 9 5 4 off Rear spigot to inner case screw 3 5 x 6 5 2 off Rear spigot blanking plate to inner case 3 5 x 6 5 2 off Grille section to inner case 3 5 x 19 4 off 6 Internal...

Page 4: ...M5 screws Stud wall 8 Recess Mounted In Stud Wall For applications including stud walls and ceilings that require top spigot configuration not suitable for Opus 95D units 1 Unpack the unit and compon...

Page 5: ...cables or switched live cables should not be placed within 50mm of other cables or on the same metal cable tray as other cables 4 1 Ecosmart Control Connections 4 1 1 Net Connections The IDC plug in...

Page 6: ...l changeover every twelve hours of run time to maximise the unit s effective life span All models shall have foam filters as standard 6 0 CONTROLS The unit has the following functions integrally mount...

Page 7: ...when the product reaches its end of life Fans motors controls actuators cabling and other electrical components can be segregated into WEEE recycling streams Sheet metal parts aluminium extrusion hea...

Page 8: ...8 27 01 22 Document Number 671398 Nuaire Western Industrial Estate Caerphilly CF83 1NA nuaire co uk OPUS 40 60 95 Installation Manual NOTES...