1.0 SAFETY INFORMATION

• 

The provision of the electrical supply and the connection of the unit to the mains must be 
carried out by a qualified electrician.

• 

Isolate from power supply before removing any covers. During installation / maintenance ensure 
all covers are fitted before switching on the mains supply. 

• 

All-pole disconnection from the mains as shown in the wiring diagram must be incorporated 
within the fixed wiring and shall have a minimum contact separation of 3mm in accordance with 
latest edition of the wiring regulations.

• 

Ducting must be securely fixed with screws to the spigot to prevent access to live parts. Duct 
runs terminating close to the fan must be adequately protected by suitable guards.

• 

Precautions must be taken to avoid the back-flow of gases into the room from the open flue of 
gas or other fuel-burning appliances.

• 

This appliance should not be used by children or persons with reduced physical, sensory or 
mental capabilities or lack of experience and knowledge, unless they have been given supervision 
or instruction concerning the safe use of the appliance by a person responsible for their safety. 
Children shall not play with the appliance. Cleaning and user maintenance shall not be carried 
out by children.

1.1 Hazard Symbols

 

GENERAL WARNING 

 

 

Signifies a general warning regarding hazard specified by supplementary information.

 

ELECTRIC SHOCK

 

 

 

This unit must be completely electrically isolated before any panels are removed. Check  

 

 

mains supply and control connections. 

 

ROTATING PARTS 

 

 

 

This unit contains fast moving rotational parts which may start automatically. It is the  

 

 

sole responsibility of the installer to adequately guard these components.

 

REFER TO INSTRUCTION MANUAL

 

 

 

Read and understand the installation and maintenance manual before installing,    

 

 

operating or maintaining this product.

Summary of Contents for NA Series

Page 1: ...uards Precautions must be taken to avoid the back flow of gases into the room from the open flue of gas or other fuel burning appliances This appliance should not be used by children or persons with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning the safe use of the appliance by a person responsib...

Page 2: ... models These IPX4 splash proof fans are specifically designed to ventilate small rooms such as toilets bathrooms shower rooms utility rooms and kitchens They are ideal for wall ceiling or panel installation and extract directly to outside or through a short length of ducting Unit Codes Operation Type Weight Kg NA100 4 Axial with remote switch operation 0 5 NA100PC 4 Axial with pull cord operation...

Page 3: ... necessary for the thickness of any ducting to be used The fan must not be exhausted into a duct which is already used for any other purpose see Approved Document F1 2006 for guidance Dismantle the fan Remove the front cover 1 by unscrewing front fixing screw 4 Using the Motor Fan Assembly 3 of the fan as a template mark the hole drilling positions to fix the fan to the wall or ceiling Drill the f...

Page 4: ...any fluorescent light fittings you intend to use H03 VV F H03 VVH2 F 7 Twin Conductor Cable 4 2 Wiring Diagrams 4 2 1 NA 100 150 with Remote Switch L N L N Double Pole Isolator 230V 50Hz 8 Wiring NA 100 150 4 2 2 NA 100PC 150PC with Pull Cord L N L N Double Pole Isolator 230V 50Hz 9 Wiring NA 100PC 150PC 4 2 3 NA 100T 100HT 150T 150HT with Light Remote Switch L N L N SL Triple Pole Isolator 230V 5...

Page 5: ...arranty 7 0 END OF LIFE AND RECYCLING Where possible Nuaire use components which can be largely recycled when the product reaches its end of life Fans motors controls actuators cabling and other electrical components can be segregated into WEEE recycling streams Sheet metal parts aluminium extrusion heating cooling coils and other metallic items can be segregated and fully recycled EPP plastic duc...

Page 6: ...6 29 10 20 Document Number 671420 Nuaire Western Industrial Estate Caerphilly CF83 1NA nuaire co uk NA Installation Manual NOTES ...

Page 7: ...7 29 10 20 Document Number 671420 Nuaire Western Industrial Estate Caerphilly CF83 1NA nuaire co uk NA Installation Manual NOTES ...

Page 8: ...8 29 10 20 Document Number 671420 Nuaire Western Industrial Estate Caerphilly CF83 1NA nuaire co uk NA Installation Manual NOTES ...

Reviews: