NuAire ECOHEATEX-2 Installation And Maintenance Download Page 1

Nuaire Limited

Western Industrial Estate  Caerphilly  United Kingdom  CF83 1NA  

T: 029 2085 8400  F: 029 2085 8444  E: [email protected]  W: www.nuaire.co.uk

1

11. 06. 15. Leaflet Number 671402

Figure 1.

ECOHEATEX-2

Heat Exchange Unit

Installation and Maintenance

Power

Status

drimaster

 

ecosmart

low energy home ventilation

Figure 2.  Heat exchange unit shown linked to DRIMASTER 

or DRIMASTER 2000 PIV unit mounted on roof joists using 

AV mounts.

PIV unit

Heat exchange unit

Diffuser

Control 773802 To be ordered separately

Power

Status

drimaster

 

ecosmart

low energy home ventilation

Figure 3.  Heat exchange unit shown linked to 

Sunwarm Tile 1 or

2

PIV unit mounted on roof joists using AV mounts. 

PIV unit

Heat exchange unit

Diffuser

Control as supplied with

Sunwarm Tile 1 or 2 PIV

unit. 

Discharge to

outside

Intake from

supply fan

Supply 

Note that

extract

grilles

must be 

fitted with

filters

Data link between heat

exchange unit and supply fan

Extract from wet rooms. 

1.0 Introduction

The unit consist of an extract fan, a cross-flow heat-

exchange unit, a by-pass damper and an intelligent 

control system.  It is designed to be used in conjunction

with a Nuaire Positive Input Ventilation unit (PIV) to

form a supply and extract system with heat exchange.

The PIV unit may be a Drimaster, Drimaster 2000 or

Sunwarm Tile 1 or 2. The unit may also be used with a

Nuaire Sunwarm system, where it would connect in

place of the PIV unit.  

This manual will only provide the installation details of the

heat exchange unit. Please refer to the relevant manual for

installation details of the relevant PIV unit.

Drimaster Leaflet number 671104

Drimaster 2000 Leaflet number 671109

Sunwarm Tile 1 or 2 Leaflet number 671380

The bypass damper will open (i.e. no heat exchange will

take place) when the following conditions are met.

The supply air inlet temperature is hotter than the extract

air inlet temperature and the user control is demanding hot

supply air temperature.

The supply air inlet temperature is cooler than the extract

air inlet temperature and the user control is demanding cold

supply air temperature.

2.0 Installation

I

nstallation must be carried out by competent personnel 

in accordance with the appropriate authority and 

conforming to all statutory and governing regulations.

The unit must be fitted/mounted on roof joists using AV

mounts (See figure 2 and 3). Details of this procedure and

Installation of the diffuser can be found in any of the three

Installation and Maintenance leaflets listed previously.

The EMC Directive 

2004/108/EC  

The Low Voltage 

directive 

2006/95/EC