Section 11
System Cleaning, Maintenance and Reinstallation
Cocoon Aqua IR Hydration Pro System
51
Flock covering will deteriorate over time, exposing metal of the protective
cover. The protective cover can heat up, and can cause a burn if a person
presses an extremity against the protective cover. It is required to annually
inspect and replace the protective flocked covers at least annually to
maintain coverage.
POINT: You should change the protective flock IR
covers at least once annually for user safety purposes, your customer
satisfaction and best business operation practices.
Usage of the unit with a missing or damaged protective flock IR covers
could cause injury and is
AT YOUR OWN RISK.
No use of the Pod is
recommend without intact and fully installed protective flocked IR covers.
LED Clusters Check
o
Check that all LED diodes are functional and lighting as expected. These LEDs
have a expected lifetime of 10,000 hours. With high usage units, we recommend
changing these
at a minimum of once every 2 years
to ensure functionality.
Check Speakers and Headphone Port for Functionality
o
Ensure speakers produce a clear, audible signal with no hum or distortion
o
Ensure when headphones are plugged in, you get a clear signal
Check Control Panel is in Working Order
o
To enter the engineering/test menu, press the “
Options
” then “
Enter
” buttons
once the unit is powered on.
o
All buttons on the control panel should respond to light touch without visible
damage to the buttons or face
Visual Inspection of the Unit
o
Ensure the hood and shell of the cocoon are in good order without visible tears or
damage
o
Ensure the neck cover is in good repair with no jagged edges, and that you can
more your hands freely through the opening
o
Ensure the hood gaskets are in good order with no tears or leaks
o
Ensure the LCD on the main display is in good order, with no missing issues and a
comfortable brightness setting
o
Ensure the Vibration Bed is in good order. It should be clean without tears or
damage. For hygienic and esthetic purposes, Sybaritic recommends replacing the
bed every 2 years.