Hole in the Wall Installation into Class 1
or Lined Flue
15.3 - CLEARANCES TO COMBUSTIBLE MATERIALS
a.
Any combustible sidewall must be at least 500mm from
the inside of the builders/fireplace opening.
b.
With all heating appliances, soft furnishings, decorations
and wall coverings may discolour or scorch if placed too
close.
c.
No combustible material, e.g. curtains must be closer than
500mm to the builders opening.
NOW PROCEED TO SECTION 16 - FIXING THE FIRE.
16.1 - FITTING THE SILICONE SEALING STRIP
16.
FIXING THE FIRE
It is very important that a good seal is achieved between the back of
the Fire’s outer frame and the front of the fireplace back panel for
safety reasons and to achieve maximum efficiency. Take the self
adhesive silicone sealing strip from the fitting kit and neatly apply to
the back flanges of the Fire’s outer frame, cutting to the appropriate
lengths as required. To ensure there is a good seal between the
base of the fire and the bottom of the fireplace opening apply a
350mm length of self adhesive silicone sealing strip under the base
of the fire at the front edge.
Fit Silicone Sealing Strip to
back flanges of outer frame
Fit 350mm length of Silicone
Sealing Strip under the base of
the fire at the front edge