background image

 

Materials included with this kit: 

 

E-AVDS-4Gx  Voice dialer 

 4G 

Antenna 

 

URL slip with path to this manual 

 

Included with E-AVDS-4Gx-P Only: 

 

100-240VAC @ 50\60Hz; 12VDC 1A AC Adapter  ("-P" model only) 

 

Country-specific Line Cord 

 

2 ea. WC-UR2 (CN1469) butt splice connectors 

 

 
 
 
OPEN THE E-AVDS-4Gx 

 

To configure the E-AVDS-4Gx(-P) for operation and to access the mounting holes, you must first open the case of the 
dialer.  
 
There are four tabs that hold the case together.  Two on the top side, and two on the bottom side.  To open the case for 
jumper placement, press down firmly on the seam of the case near the tabs on one side of the case and snap the case 
halves apart.    

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Tabs 

With the rear of the case removed, two counter-
sunk mounting holes are provided on the rear 
cover.   Use these to secure the E-AVDS-4Gx to 
your desired mounting location.  

Mounting Holes 

Rear Cover

Summary of Contents for E-AVDS-4G1

Page 1: ...range of a configurable threshold o Mini SIM card supporting SMS messaging required not included Stores one outgoing voice message of up to 20 seconds and sends one SMS message of up to 70 bytes E AV...

Page 2: ...n and to access the mounting holes you must first open the case of the dialer There are four tabs that hold the case together Two on the top side and two on the bottom side To open the case for jumper...

Page 3: ...et the normal relay state to Normally Closed apply the J1 and J2 jumpers to the center and left pins In this configuration a relay open condition will trigger an alert state activating the dialer CAUT...

Page 4: ...Connect the cable from the E AVDS 4Gx to the E xD according to one of the following diagrams Note The attached cable is 700mm 27 inches long but can be extended up to 100 feet with any 3 conductor 22A...

Page 5: ...5...

Page 6: ...ator OFF FULL NETCOM module is powered OFF or not working 200ms ON and 200ms OFF data communication built 800ms ON and 800ms OFF network register successful LED indicator ON sending alarm or data comm...

Page 7: ...1 ENTER If the password you entered in is correct the LED will display 5 and then log into the Programming Mode If the password you entered is incorrect the LED will display E and return to the workin...

Page 8: ...s begin recording and then begin talking and recording after which you will hear Du The dialer will stop automatically and playback the voice message after it has finished recording The User can stop...

Page 9: ...s the password they can open the back cover of the dialer power the Dialer ON and press the RESET BUTTON see page 2 Password will be changed to the default one 0911 but all other programmed informatio...

Page 10: ...ialization the alarm will not be sent 2 Press ENTER to return to working state after finishing an operation If ENTER is not pressed and the LED displays 5 programming state it will lead to alarm commu...

Page 11: ...140 F 4 to 60 C Dimensions WxDxH 5 87x3 54x1 25 in 149x90x32 mm Included Antenna dimensions WxDxH 1 18x1 18x3 9 in 30x30x99 mm Part Supported Country Supported Bands Supported Frequencies in MHz FDD L...