NVR-3000 OPERATION MANUAL & INSTALLATION MANUAL
NVR-3000 OM.E 20210412-02
77
Necessary settings are needed for NPT-100 before properly working with NVR-3000. Please refer to the manual
supplied by the printer maker. The settings include the following parameters:
- Serial port setting
The output of NPT-100 should be set as SERIAL.
- Baud rate setting
NPT-100’s baud rate can be 75, 110, 150, 300, 600, 1200, 2400, 4800, 9600, 19200bps. As the default rate, both
NVR-3000 and NPT-100 have been set at 4800bps in factory.
5.3.4 CONNECT TO (S)VDR
Please refer to the attached drawings for the connection and wiring.
5.3.5 CONNECT TO INS/BAM
Please refer to the attached drawings for the connection and wiring.
5.4 MMSI & ATIS ID Setting
When the VHF radio is powered on for the first time, typically during installation, the vessel’s MMSI number can
be entered. Hereafter the MMSI number is briefly displayed after powered on. The MMSI is a unique, 9-digit
identifier assigned to own ship.
Do the following to set own ship’s MMSI.
①
Click
[MENU]
–
[DSC]
– [MMSI
SETTING
] on Main screen.
②
With [
MMSI
] selected, the screen shown below appears. Click
[MMSI]
/
[ATIS ID]
to enter the MMSI/ATIS
ID. Click
OK
to confirm the input.
Summary of Contents for NVR-3000