NSP D6M A1A Installation Manual Download Page 15

 

 

                                                                                                    14                                                                                                Ver. 0.2 
 

 

Commissioning & Maintenance 

All work in commissioning and maintenance of a system must be performed by a qualified PV technician. 

 

Bypass Diode 

-

 

Modules have bypass diodes integrated in the junction box and are wired in parallel with series string. 
In the unlikely event of diode failure, it is recommended to contact with NSP or local agent for 
checking / replacing bypass diodes. 

-

 

Be cautious of electricity shocks while commissioning and maintaining the solar power system. 

 

Testing 

-

 

Test all electrical and electronic components of the system before commissioning. 

 

Maintenance 

-

 

Clean the module glass when it’s dirty, use water and a soft sponge or cloth for cleaning. A mild, 

non-abrasive cleaning agent can be used to remove sticky dirt. 

-

 

Check the electrical and mechanical connections regulatory to verify they are clean, secure and 
undamaged. 

 

 

Disclaimer of Liability 

 

-

 

The use of this manual, the installation conditions or methods, operation, use and maintenance of PV 

modules are beyond NSP’s control, NSP does not accept responsibility and expressly disclaims liability 
for loss, damage or expense arising out of or in any way connected with such installation, operation, 

use or maintenance.   

-

 

No responsibility is assumed by NSP for any infringement of patents or other rights of third parties, 
which may result from use of the PV modules. No license is granted by implication or under any patent 

or patent rights. 

-

 

This manual information is based on NSP’s knowledge and experience and is believed to be reliable. 

Such information including product specification (without limitations) and suggestions do not 

constitute a warranty, expresses or implied. NSP reserves the right to change the manual, the PV 

product, the specification or product information sheet without prior notice. 

Summary of Contents for D6M A1A

Page 1: ...ters 7 Li Hsin 3rd Rd Hsinchu Science Park Hsinchu 30078 Twain Tel 886 3 578 0011 Fax 886 3 578 1255 E mail Sales module nsp com INSTALLATION MANUAL D6M_BxA Series D6M_B1A D6M_B2A D6M_B3A D6M_B5A D6M_...

Page 2: ...2 Content General information Safety precaution for the installing solar PV system Fire safety Mechanical installation Electrical installation Commission Maintenance Disclaimer of Liability 2 2 3 4 9...

Page 3: ...proper mounting systems designed for appropriate mechanical loads resulting from wind and snow and the proper weight of the modules It is suggested that completely cover the module with an opaque mat...

Page 4: ...25 percent 80 percent de rating which may be applicable Fire Safety NSP modules are rated as Fire Class C according to UL 790 Standard To use components such as earth ground fault circuit breakers fus...

Page 5: ...eel made unless otherwise specified it should use corrosion proof fixing material The module mounting structure must be made of durable corrosion resistant and UV resistant material There are two appr...

Page 6: ...modules can be mounted by using clamps Clamp A and Clamp B which is designed for solar modules as shown in Fig 2 1 Modules must be mounted at 4 symmetrical points by the means shown in Fig 2 2 and Fi...

Page 7: ...g components must be corrosion proof material The applied torque is about 8 N m The modules are supported parallel to surface of the building wall or roof Sufficient clearance recommended is 140 mm be...

Page 8: ...lamping at Module Short Side Frame Module Series Module Dimension Acceptable Clamping Range W 4 D6M_B1A D6P_B1A 1015 x 992 x 40 mm 248 mm D6M_B2A D6P_B2A 1330 x 992 x 40 mm 248 mm D6M_B3A D6P_B3A 1640...

Page 9: ...8 Ver 0 2 Clamping at Module Long Side Frame Illustration Load 2400 Pa Load 5400 Pa...

Page 10: ...rting surface or frame Electrically ground the frame of the module or array to avoid the hazards of electric shock and fire Bonding shall be by a positive means such as clamping riveting bolted or scr...

Page 11: ...f fixing material as shown in Fig 3 2 The grounding wire should not be smaller than 12 AWG The grounding wire should be 2 meters in length multi conductor and rated of 105 C and 600V Recommended torqu...

Page 12: ...use tin plated solid copper lay in lug with a stainless steel set screw capable of accepting a 4 12 AWG copper conductor e g ILSCO GBL 4DBT Burndy CL50 1TN Length of bolts should not be more than 20m...

Page 13: ...dule Illustration B as below shows 4 modules connected in parallel If modules are connected in parallel the total current is equal to the sum of individual module current Connecting modules in paralle...

Page 14: ...We recommend that all wiring and electrical connections comply with the National Electrical Code NEC For field connections use the solar cable with appropriate cross section according to TUV 2 PfG 11...

Page 15: ...ns regulatory to verify they are clean secure and undamaged Disclaimer of Liability The use of this manual the installation conditions or methods operation use and maintenance of PV modules are beyond...

Reviews: