6
NOTICE
NOTICE
Do this adjustment function after your purchase. Once it is adjusted, it will be memorized, and there is no need to
do this everytime.
· The displayed air pressure is only a guideline. Measure the correct air pressure with the air gauge.
· The unit of displayed air pressure is "kgf/cm
2
". For other unit, refer the bellow.
ex) 0. 0.0MPa
.0 0.MPa
3.0 0.3MPa.
NOTICE
· Default value is set to "0.5" .
· When the air pressure is not between "0.3" - ".0", it is displayed "Eb", and will not be memorized
) Press M2 key and Rotation Speed Adjustment Key( ) at the same time for more than 3 seconds.
2) With alarm sound, Indicator will change to "C" (Lower air pressure limit setting mode).
3) By pressing the FWD/REV Rotation key, Speed Indicator shows " 0.0" and "Eb" mutually.
4) By stepping the Foot Pedal of the delivery unit, Indicator shows the present air pressure.
Fig.9
6. Convenient Functions
5-5
Select FWD/REV rotation using the FWD/REV Select Key. (Fig. 9)
Lamp ON
REV
Lamp OFF FWD
5-6
The micromotor operation will be controlled by the air switch/Foot
Pedal of the delivery unit.
6-1 Foot Air Calibration
(
Unit of Display
=
kgf/cm
2
)
By using this function, it enables you to use the maximum speed, 40,000 min
-
(rpm), even though the air pressure of the
delivery system is not high enough, by setting upper and lower limit of the air pressure.
5) Control the Foot Pedal of the delivery unit, and maintain the air pressure between "0.3 " - ".0". Press M2 key for
more than 3 seconds to memorize the lower limit of the air pressure.
Fig.8
5-4
Set the maximum speed using the Rotation Speed Adjustment Key
(
) . (Fig. 8)
Decrease
Increase
Indicator
FWD/REV Lamp
PUSH