Appendix 1: Monitoring Input/Output Signals
IO: Input/Output Monitor (B3 and 23 type Driver Units)
[Example 1] Check if the start command RUN for positioning with Programmable Indexer
is inputted.
(1) Confirm that the colon (:) is on the display of the Hndy Terminal.
(If the colon (:) is not on the display, press the ENT key once.)
:_
(2)
:IO_
O
I
(3)
:IO/RP_
R
P
/
(4) Press the
ENT key for execution, then the readout will be on the dixplay.
:IO/RP
ABCDEFGHIJKLM
00100000/0000
********/****
ENT
RUN
(5) Press the BS key after checking the readout. The readout remains on the screen and
other command won’t be accepted unless the BS
is not pressed.
ABCDEFGHIJKLM
00100000/0000
********/****
:_
BS
Explanation
l
The checking procedures described above confirm that the RUN input, start command for
positioning with Programmable Indexer, is ON as the readout of the signal is 1.
à
In case of above [Example 1], the readout of Input/Output signals will be observed and
displayed on the screen until the BS key is pressed.
à
If the signal changes ON and OFF (ON
⇔
OFF) while monitoring the state of
Input/Output signals, the readout will follow the changes with 1 and 0 (1
⇔
0) as well.
à
However, if the step (3) of the procedure of [Example 1] is omitted, the readout will be
one-shot right after the ENT key is pressed.