
— 8-38 —
B
B
3
3
t
t
y
y
p
p
e
e
B
B
5
5
t
t
y
y
p
p
e
e
8. Glossary of Command and Parameter
2
2
3
3
t
t
y
y
p
p
e
e
2
2
5
5
t
t
y
y
p
p
e
e
«
PE: Program Error, Alarm Type
Format
: PE data
Data
: 0, and 2
Shipping set
: 2
Default :
0
l
This command sets the alarm output mode for “Program error.”
Setting
DRDY output
OVER output
PE0
Does not change. Does not change.
PE2
Does not change.
Closed.
l
Regardless of the setting of the PE command, the 7 segments LED and the TA command reports
the alarm state.
l
The TS and ?PE command reports the current setting.
PG: Position Gain
Format
: PG data
Data
: 0.010 to 1.000, or /AJ (adjusting mode)
Shipping set
: 0.100
Default
: Not available
l
Sets proportional gain of the position loop.
l
The TS or ?PG command reports the current setting.
l
The PG/AJ starts the adjusting program.
l
It is automatically adjusted when thee LO data or the SG data is changed.
l
The LO data and the SG data will be cleared to 0 when the PG data is changed.
«
PH: Program Home Return
Format
: PH data
Data
: 0 -----Automatic Home Return invalid
1 -----When the power is turned on, the PH executes Home
Return only if the home position is undefined.
2 -----Executes automatic Home Return every time before
execution of a positioning with the Programmable Indexer.
Shipping set
: 0
Default :
0
l
This is to execute Home Return automatically before an execution of positioning with the
Programmable Indexer.
l
The setting makes the HS command unnecessary, thus saves a program area equivalent to one
channel.
l
The TC/AL or ?PH command reports the current setting.