3

• Compact design.
• Able to operate for approx. 2 continuous hours at the rated load. (Dependent upon use conditions.)
• A large and eye-friendly LCD panel has been adopted on the control unit.
• Programmable up to 9 programs (memory setting).
• The auto reverse function is activated depending on the load. A wide variety of functions such as “auto reverse”, “auto 

stop” and “auto reverse off” are available. Combined with such functions nine different operation programs are 
memorable.

• The rotation of the motor handpiece can be activated by the ON/OFF button of the motor handpiece or the Foot Control 

(option).

• The motor handpiece can be turned on and off by pressing the ON/OFF button alternatively. In addition, ON by keep 

depressed and OFF by releasing it is possible.

• The motor handpiece softly starts. Since it makes a brief stop before it starts in the reverse rotation, there are no 

vibration and shocks during this changeover.

• The feedback circuit is built in. It maintains rotation at a constant speed even when the load on the motor handpiece 

changes.

• Has energy saving feature. The power of the motor handpiece automatically turns off when there are no operations for 

10 minutes. (Auto power-off function)

• The contra angle heads provided for this product are all autoclavable up to 135°C (excluding the motor handpiece).

1. FEATURES

Fig. 0

• Use the specified batteries for this product. Never use any other batteries than those that NSK specifies.
• Do not disassemble or alter the device.

HelveticaNeue 47Light Condensed   8pt x 9.5pt
So this is Xmas   And what have you done   Another year over   And a new one just begun   And so this is Xmas   I 
hope you have fun   The near and the dear one   The old and the young   A very Merry Xmas   And a happy New 
Year   Let's hope it's a good one   Without any fear   And so this is Xmas   For weak and for strong   For rich and 
the poor ones   The world is so wrong   And so happy Xmas   For black and for white   For yellow and red ones   

CAUTION

HelveticaNeue 47Light Condensde  8pt x 9.5pt
When you wish upon a star Make no difference who you are Anything your heart desires Will come to you  If your 
heart is in your dream No request is too extreme When you wish upon a star As dreamers do  Fate is kind She 
brings to those who love The sweet fulfillment of Their secret longing  Like a bolt out of the blue Fate steps in and 
sees you through When you wish upon a star Your dream comes true 

NOTICE

So this is Xmas 

DANGER

• During vibration, the motor handpiece and the motor handpiece cord may affect computer and LAN cable. Noise 

could be heard during operation near a radio receiver.

• The motor handpiece consumes electricity very slightly even when the power supply is off. In addition, fully-charged 

rechargeable batteries, in general, discharge gradually over time even though it is not used. It is recommended to 
recharge the batteries just before use.

• When the motor handpiece stops automatically by detecting a low battery voltage, turning on the power again after a 

while may not detect the low voltage immediately. This is not a failure, but due to battery characteristics. Since the 
voltage drop does not coincide with the remaining battery capacity, consider it only as a yardstick.

• Recharge rechargeable batteries after they deplete as much as possible. Repeating short-time use and subsequent 

recharging may shorten their operating time due to the “memory effect.” Batteries may recover after repeating 
complete discharge and full charge for a few times. (This product is equipped with a “Refresh Mode” for this 
purpose.)

• The used Nickel Metal Hydride Batteries are recyclable, but their disposal may sometimes not be permitted by the 

country. Return them to your dealer.

• When disposing of the control unit and Foot Control (Option), follow the instructions of your local government for 

disposal, as they contain materials which may become industrial waste.

• When discarding the contra angle head and motor handpiece, dispose of them as medical waste.
• Users are responsible for operational control, maintenance and inspection.
• Store the system in the place where the temperature is at -10-60°C (14-140°F), humidity at 10-85% RH, 

atmospheric pressure at 500-1060 hPa, and the system is not subject to air with dust, sulfur, or salinity.

• When trouble is found, send to dealer.
• This product does not consider patient’s age (except infants), gender, weight or nationality.
• No special training is required for this device.

• ENDO-MATE DT should not be used adjacent to or stacked with other equipment and that if adjacent or stacked use 

is necessary, ENDO-MATE DT should be observed to verify normal operation in the configuration in which it will be 
used.

NOTICE

• Use by medical professional, such as doctor or dental hygienist, is intended.
• This product is NOT built as waterproof. Do not spill water or a chemical solution onto or into the motor handpiece or 

control unit. Failure to do so may result in fire or electric shock due to a short-circuit or rusting.

• Keep away from patients with cardiac pacemakers.
• If you should notice battery fluid leak within the control unit, deformation of the control unit casing or partial 

discoloring, immediately stop use and contact your dealer.

• Should the leaking battery fluid get into your eyes, immediately wash eyes thoroughly with clean water and see your 

doctor. Failure to do so may result in loss of sight.

• Should the battery fluid leak and adhere to skin or clothing, immediately wash the exposed skin thoroughly with clean 

water and completely wash away the fluid. Failure to do so may result in skin complications.

• If the product has not been used for a long period, remove the batteries from the product to avoid fluid leak.
• When installing the product, provide space of approximately 10cm around the Control Unit for easy access to the inlet 

and the Power Cord

• The system may present a possibility of malfunction when used in the presence of electromagnetic interference 

wave. Do not install the system in the vicinity of the device which emits magnetic waves.

• There is the judgment that applies this product to a patient in the user side.

WARNING

• Exercise sufficient care in using the product by giving patient safety first priority.
• The product is to be used only for dental treatment by qualified personnel.
• Use the NSK AC Adaptor for this product. Never use any other AC Adaptors.
• Observe the allowable rotation speed which the file manufacturer specifies for use.
• Do not use a bent, damaged, deformed or non-ISO-conforming file. Using such a file may result in personal injury due 

to its unexpected breaking or flying off during rotation.

• Do not use or leave the product in a high-temperature environment such as under strong direct sunlight, in a car 

under a blazing sun, by a fire, or near a stove.

• Check the product before use by rotating it, paying attention to looseness, vibration, noise and temperature (heat 

generation). If any abnormal condition is found even slightly at that time, immediately stop use and contact your 
dealer.

• Do not allow any impact on to the Product. Do not drop the Product.
• Do not attempt to disassemble the product or tamper with the mechanism.
• Always clean the shank of the file to be installed. Allowing dirt to enter the chuck could cause loss of concentricity 

and deterioration of chucking force.

• Before changing the head or File, turn off the power of the motor handpiece. Changing with the power kept on may 

cause unintended rotation.

• Pay attention to the direction of batteries when setting. Forcible setting in the wrong direction may cause damage 

and fluid leakage due to a short circuit.

• Do not allow conductive materials such as wires, safety pins, etc., to enter into the battery case.
• If chemical, solvent or antiseptic solution is deposited on this product, immediately wipe it away. Discoloration or 

deformation may occur if left as it is.

• The system functions normally in the environment where the temperature is at 10-40°C (50-104°F), humidity at 

10-85% RH, atmospheric pressure at 700-1060hPa, and no moisture condensation in the Control Unit. Use at 
outside of these limits may cause malfunction.

• ENDO-MATE DT needs special precautions regarding EMC and needs to be installed and put into service according to 

the EMC information.

• Portable and mobile RF communications equipment can affect ENDO-MATE DT .
• The use of ACCESSORIES, transducers and cables other than those specified, with the exception of transducers and 

cables sold by the manufacturer of ENDO-MATE DT as replacement parts for internal components, may result in 
increased EMISSIONS or decreased IMMUNITY of ENDO-MATE DT . 

CAUTION

Summary of Contents for ENDO-MATE DT

Page 1: ...OPERATION MANUAL Please read this Operation Manual carefully before use and file for future reference OM E0202E 002 Motor Handpiece System for Root Canal Enlargement...

Page 2: ...this Operation Manual for future reference Read these safety cautions thoroughly before use and operate the product properly These indicators are to allow you to use the product safely and prevent da...

Page 3: ...ged deformed or non ISO conforming file Using such a file may result in personal injury due to its unexpected breaking or flying off during rotation Do not use or leave the product in a high temperatu...

Page 4: ...though it is not used It is recommended to recharge the batteries just before use When the motor handpiece stops automatically by detecting a low battery voltage turning on the power again after a whi...

Page 5: ...luding motor handpiece cord Fig 1 2 3 8 10 9 1 12 4 5 6 7 11 Option Control Unit Operation Panel See Fig 2 Operation Panel and LCD Panel LCD Panel See Fig 2 Operation Panel and LCD Panel Error codes a...

Page 6: ...pending on the rotation speed Operation Panel and LCD Panel Fig 2 LCD Panel This indicates that all displays are lighted TORQUE Key The torque limit values can be changed If the speed is to exceed the...

Page 7: ...available at 1 1 4 1 10 1 16 1 and 20 1 REVERSE Key The rotational direction of the file can be changed by this key It can also be changed while the file is in motion The alarm sounds during reverse...

Page 8: ...on of the power LCD The mark of the present remaining amount of the batteries is displayed regardless of the ON or OFF position of the power The mark will be animated when the batteries are being char...

Page 9: ...he mark of the plug cast down Fig 5 You do not have to connect the Foot Control if you intend to use this product without the Foot Control 4 HOW TO CONNECT EACH PART To remove the plug hold the plug r...

Page 10: ...imes The temperature of the batteries is measured during charging Proper charging cannot be preformed if the charger is placed in an environment which is subject to sharp temperature change next to wi...

Page 11: ...t gear ratio is selected according to the contra angle head in use an adequate rotation speed and torque limit value can be set 4 Select the rotational direction by pressing the REVERSE key The key ch...

Page 12: ...tion 5 Operation 1 Start the motor handpiece to pressing the ON OFF button briefly Press the button again may stop the handpiece Alternate operation Keep pressing ON OFF button more than a second the...

Page 13: ...or more than one second If the program number is changed by the PROGRAM key without pressing the MEMORIZE key the initially memorized preset values remain Cancel function NOTICE 6 Completion of Medica...

Page 14: ...play at the time of charging At the same time the CHARGE lamp flashes slowly 5 Leave it as it is The batteries are discharged and recharged automatically 6 Hold down the POWER key for a while when you...

Page 15: ...ad for 2 3 seconds Fig 12 2 Cleaning Motor Handpiece When the motor handpiece becomes dirty wipe it off with a cotton cloth moistened with rubbing alcohol 7 CLEANING Do not lubricate the motor section...

Page 16: ...out the old batteries and pull out the cord holding it at the connector Fig 14 4 Insert the connector of the cord of new batteries into the connector in accordance with the polarity indication label...

Page 17: ...on of the circuit may be suspected Contact your dealer Malfunction of circuit The motor handpiece is locked at the time of the auto reverse mode Malfunction of circuit High load was continuously appli...

Page 18: ...batteries is high An error code is displayed Check the connection Check the connection Charge the batteries or use the AC Adaptor Insert batteries or use the AC Adaptor Contact your dealer Check the c...

Page 19: ...t is rotated by the Foot Control Option Clean or replace the contra angle head Contact your dealer Check the ON OFF button Contact your dealer Check the Foot Control Option Remove the foot control Opt...

Page 20: ...tronic equipment The ENDO MATE DT is suitable for use in all establishments including domestic establishments and those directly connected to the public low voltage power supply network that supply ne...

Page 21: ...electromagnetic immunity The ENDO MATE DT is intended for use in the electromagnetic environment specified below The customer or the user of the ENDO MATE DT should assure that it is used in such an e...

Page 22: ...vent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment transmitters and the ENDO MATE DT as recommended below according to the maxi...

Page 23: ...Specifications are subject to change without notice 2014 11 20 02 M The EU directive 93 42 EEC was applied in the design and production of this medical device...