NSK ASTRO-E 250 Operation Manual Download Page 6

Collet CHK-□□ 

Collet Cap

Collet CH5-□□ 

Collet Cap

Grindstone Axis AGM-03

Metal Saw Axis KCH-03

Metal Saw Axis KCH-01

Collet Chuck CHG-□□ 

Collet Chuck CH8-□□ 

Drill Chuck Axis DCH-J0K 

(Jacobs Taper #0) 

(Use less than 3,000min

-1

) 

Drill Chuck Axis DCH-J0 

(Jacobs Taper #0) 

(Use less than 3,000min

-1

) 

Metal Saw Axis KCH-02

Collet Chuck CHS-□□ 

Metal Saw Axis KCH-01N

Drill Chuck Axis DCH-J0N 

(Jacobs Taper #0) 

(Use less than 3,000min

-1

) 

Collet Chuck CHM-□□ 

Grindstone Axis AGM-01

Control Unit NE-72

Motor EM-250

EM-255

Speed Reducer 
ARG-01 

(Reduction Ratio 1/3.92) 

Speed Reducer 
ARG-02 

(Reduction Ratio 1/15.39) 

Spindle NR-302 
             NR-2350

Spindle NR-301

Spindle NR-310

Slim Shaft Spindle 

AMH-300

Slim Shaft Spindle 

AMH-301

Spindle NR-600

Spindle NR-601

90゜

Angle 

Spindle 

RA-100 

(Reduction Ratio 1/2.67) 

90゜

Angle 

Spindle 

RA-200 

(Reduction Ratio 1/1.5) 

Spindle 

RAS-100

ASTRO-E 250 ATTACHMENT SYSTEM CHART

¡

Use angle type attachments such as RAS-100, RA-100
and RA-200 with Speed Reducer in a low speed.

¡

The O.D. of metal saw should be less than 

φ

30

A

(

φ

1.18") and can be used for nonferrous metal such

as brass and alminium with the thickness of less than
1.5

A

.

¡

In case of using drill chuck, keep the speed less than
3,000min

-1

.

P. 9

TROUBLE SHOOTING

Please check the following points before asking for repair.

Unit

Motor

Trouble

Check Points

Probable Cause

Action Taken

Power Source lamp
does not light up.

¡

Power plug is not connected

properly.

¡

Fuse is brown out.

¡

Connect the plug properly.

¡

Replace the fuse 250V3. 15A.

Overloaded so often.

Wait for the light up the power
source lamp.

Check if the reset lamp is light up.

Release the reset circuit. 
(Ref. P. 6)

Connect the plug properly. 
(Ref. P. 4)

When Motor Cord Plug is not
connected, Reset Lamp does not
turn off. (Ref. P. 4)

Switch to either FWD / REV of the
converting switch.

FWD / REV Switch is OFF.

ON / OFF terminal is not
connected properly.

Connect the ON / OFF terminal
properly. (Ref. P. 4)

Reset lamp
does not turn
off even if the
reset circuit is
released.

Check the
connection of
motor plug if it
is tight.

When Manual
mode, motor
does not run
even if either
FWD / REV
Switch is ON.

When Auto
mode, motor
does not run
even if either
FWD / REV
SWItch is ON.

Motor
does not
run.

Power
Source
Lamp
does not
light up.

Spindle

Trouble

Probable Cause

Action Taken

Run-out of bur.

Check if dirts are in the collet or
spindle.

Clean the collet and the inside of
spindle.

Collet Cap is not mounted
properly.

Mount Collet Cap properly on the
Collet.

Wear of ball bearing.

Repair at authorized NSK repair shop.

Repair at authorized NSK repair
shop.

Noise and vibration occur 
during rotation.

¡

Foreign materials are in the ball

bearing.

¡

Wear of ball bearing.

Bur shank is bent.

Replace with a good bur.

P. 10

ASTRO-E250̲K0155E.r1̲e̲のコピー  05.6.20 9:24 PM  ページ 11

Reviews: