POOL/SPA CONTROL
ACCESSORIES
INSTALLATION
OPERATION &
SERVICE MANUAL
MODEL TPE24VA VALVE ACTUATOR
Suitable for Pool / SPA Equipment Applications
MOUNTING ACTUATOR ON TOP OF VALVE
Screws (4)
Water flows into or
out of the valve
Figure 1. Standard Plumbing
Port A
Port B
(Common Port)
Port C
1. Unscrew the hold-down knob and remove handle from valve
shaft. Set aside the knob and handle for later use.
2. With a Phillips screwdriver, remove the four screws from the
valve body as shown in Figure 1.
3. Turn the actuator over and observe the teeth as shown in
Figure 2.
4. Place the actuator over the valve shaft so the small tooth
engages with the small slot in the valve shaft. See Figure 2.
5. Rotate the actuator until the actuator posts line up with the four
holes so it matches one of the mounting positions shown in
Figure 3. See table below for descriptions of mounting options.
Mounting Options
The actuator can also be mounted on top of a valve in four different
positions as shown in Figure 3. Depending on the plumbing of the
valve and mounting position of the actuator, the cams inside the
actuator may have to be reset. (See next section.)
6. Use the supplied four long stainless steel screws to attach the
actuator to the valve.
7. Use the hold-down knob set aside in step 1 to connect the
handle to the valve shaft.
8. Connect power supply cord to a CLASS 2 CIRCUIT ONLY,
rated 24V nominal, 4A or 100VA maximum.
Place actuator on valve so small tooth aligns
with small slot.
SMALL SLOT
SMALL TOOTH
VALVE
BOTTOM
VIEW OF
ACTUATOR
Figure 2. Actuator Mounting
Port A
Port C
Port B (Common Port)
Figure 3. Mounting Positions
ITEM I
ITEM II
ITEM III
ITEM IV
WARNING
Risk of Electrical Shock
• TO BE CONNECTED TO A CLASS 2 CIRCUIT ONLY
• ALL WIRING MUST COMPLY WITH ALL STATE AND LOCAL ELECTRICAL CODES INCLUDING THE
NATIONAL ELECTRICAL CODE AND/OR CANADIAN ELECTRICAL CODE.
READ, FOLLOW & SAVE THIS INSTRUCTION MANUAL
ELECTRICAL RATINGS : 24 Volts, 60 Hz, 0.75 Amps.
Normal Operation Duty Cycle: 1 minute ON (Max), 8 minutes OFF (Min). These
values may be temporarily exceeded during installation testing and adjustment.
Standard Plumbing
- A three-port valve is the port B (middle)
being the incoming (common) port and A and C ports are the outlet
ports (see Figure 1).
Standard Actuator Mounting
- The main body of the actuator
is over port B as shown in Item II of Figure 3.