Implemented MDB commands
Byte 1
Byte 2
Command
Data
[Bytes
expected/
returned]
00h
–
Reset
[0/ACK]
01h
–
Status
[0/23]
02h
–
Tube Status
[0/18]
03h
–
Poll
[0/1..16]
04h
–
Coin Type
[4/ACK]
05h
–
Dispense
[1/ACK]
07h
00h
Expansion Command Identification
[0/33]
07h
05h
Expansion Command Status
[0/2]
MDB status and error codes (reply to poll)
Byte 1
Byte 2
Meaning
01h
–
Return lever pressed
05h
–
Two coins (coin inserted too quickly)
08h
–
Program error/data memory
09h
–
Accepted coin sensor (CP3/CP4) did not detect
-
within specified measuring time
0Bh
–
Reset occurred
0Ch
–
Coin pile-up
20h – 3Fh
–
Unknown coin rejected (slug counter)
40h – 4Fh
00h
Coin 0–15 accepted
70h – 7Fh
00h
Coin 0–15 rejected
Summary of Contents for G-13.mft MDB/S1
Page 2: ......
Page 6: ......
Page 43: ...G 13 mftMDB S1 TECHNICALDATA 43 National Rejectors Inc GmbH Buxtehude ...
Page 49: ...G 13 mftMDB S1 TECHNICALDATA 49 National Rejectors Inc GmbH Buxtehude View from the side ...
Page 52: ...TECHNICALDATA G 13 mftMDB S1 52 National Rejectors Inc GmbH Buxtehude View from the side ...
Page 54: ...TECHNICALDATA G 13 mftMDB S1 54 National Rejectors Inc GmbH Buxtehude View from right ...
Page 56: ...TECHNICALDATA G 13 mftMDB S1 56 National Rejectors Inc GmbH Buxtehude View from right ...