NRG INSTRUCTIONS
SRA System | Soiling Measurement Kit
SRA Soiling Measurement Kit Instructions
Rev. 6.0
[email protected] | Page 19
19 December 2018
I
sc
Soiled
:
Expand Channel 26 and choose “Custom Analog 0-5V” from the “Load From Defaults” drop-
down menu.
This will auto select “P-SCM #9132, (0 to 5) V, SE Input, Constant 12V EXC” from the
SymphoniePRO Signal Conditioning Module (P-SCM)” drop-down menu.
Edit the Description, Scale Factor, Offset and Units as show in the image below:
3.1.2 Scale Factors and Offsets Summary
Table 3-1
Signal Input
Channel
Input Type
Scale Factor
Offset
Units
TempCLEAN
21
Analog 0-30 V
13
-40
Deg. C
I
sc
CLEAN
24
Analog 0-5 V
0.3125
0
A
TempSOILED
22
Analog 0-30 V
13
-40
Deg. C
I
sc
SOILED
26
Analog 0-5 V
0.3125
0
A