NRG INSTRUCTIONS
SRA System | Soiling Measurement Kit
SRA Soiling Measurement Kit Instructions
Rev. 6.0
[email protected] | Page 15
19 December 2018
2.6: Affix Interface Module to DIN rail & wire snesor signals to the logger wiring panel.
Attach the wired Interface Module onto the DIN rail and connect the other end of the 4C cable to the
wiring panel. Connect the two IMT back of the panel temprature sensors to the wiring panel.
The Soiling Measurement Kit consists of four inputs:
Two 0-30 V temperatures inputs - Temperature ‘CLEAN’ & Temperature ‘SOILED’:
o
Each input requires a #9135 P-SCM cards.
o
The sensor signals come from the IMT amplifier boxes.
o
Both sensors require 12v DC excitation voltage.
Two 0-5 V inputs PV inputs - I
sc
CLEAN and I
sc
SOILED:
o
Each input requires a #9132 P-SCM cards.
o
The sensor signals come from the Interface Module.
o
The I
sc
outputs require a single 12V excitation (EXC) and ground connection (GND).
Table 2-2 provides an example of how the sensor wires can be connected to the wirng panel (any
combination of P-SCM channels can be used ~ 20-26).
Channel
Sensor Output
Wire Color
Terminal
21
Temprature
‘CLEAN’
Power +
Red
EXC
Power/Signal –
Thin Black
GND
Signal Output
Brown
SIG +
Sheild
Thick Black
SHD
22
Temprature
‘SOILED’
Power +
Red
EXC
Power/Signal –
Thin Black
GND
Signal Output
Brown
SIG +
Sheild
Thick Black
SHD
24
I
sc
CLEAN
Interface Module Power*
Red
EXC
Interface Module Ground*
Black
GND
IscCLEAN PV Signal
Orange
SIG +
26
I
sc
SOILED
IscSOILED PV Signal
White
SIG+
*Interface Module Power and Ground can be placed on either IscClean or IscSoiled channel
Table 2-2: Example Configuration