![NPM Motionnet G9001A User Manual Download Page 30](http://html1.mh-extra.com/html/npm/motionnet-g9001a/motionnet-g9001a_user-manual_1713900030.webp)
DA70131-1/3E
I-24
4-7. Interrupt status
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
CAE3 CAE2 CAE1 CAE0 ERA3 ERA2 ERA1 ERA0
LNRV
0
EDN5 EDN4 EDN3 EDN2 EDN1 EDN0
Bit
Symbol
Description
0 to 5
EDN0 to 5
These bits show the number of the device which has an error, when EDTE = 1 or
ERAE = 1. These details are stored until the next time an error occurs.
6
(Not defined)
Always 0.
7
LNRV
When a local device is not receiving data, this bit is 1.
When the data communication terminates with an error (EDTE = 1), and if a local
device cannot receive data from the center device (the local device does not
respond), this bit becomes 1. When the local device has received the data
(communication data from a local device is interrupted by a communication error
and the center device does not receive the data normally, you have to check
whether the local device received the data normally), this bit returns to 0.
This condition is stored until the next time an error occurs.
8 to 11
ERA0 to 3
These errors occur even if a local device received data normally but the packet
details of the data do not match at the local device.
When this error occurs, the center device will store one of the following codes in
these bits. This condition is stored until the next time an error occurs.
Code
Error conditions
0001
I/O setting information in the device information area in the
center device is not identical to the I/O port combination
(specified using the PMD terminal) on the local device.
0010
An I/O device(G9002A) received a data communication
frame.
0011
A data device received frames larger than the receiving
buffer capacity of the data device.
12 to 15
CAE0 to 3
If the CPU tries to access the G9001A illegally, it will store one of the following
codes in these bits. The code is stored until the next time an error occurs.
Code
Error conditions
0001
The CPU tried to write a cyclic communication start
command but the number of devices used is set to zero.
0010
When having tried to write a start sending command
without putting any data in the data sending FIFO.
0011
While the DBSY = 1, a device tried to do one of the
following:
(1) Reading or writing to the transmitting or receiving FIFO.
(2) When having written a system start command or a data
communication start command.
0100
When having tried to communicate with a device which had
device information area bit 7 set to 0 (It means that the
device is not used).
ISTB1
ISTB0
ISTE
Summary of Contents for Motionnet G9001A
Page 1: ...DA70131 1 3E G9001A G9002A User s Manual Center device I O device Remote I O Remote Motion...
Page 7: ...DA70131 1 3E I 1 I Center device G9001A User s Manual...
Page 8: ...DA70131 1 3E I 2...
Page 50: ...DA70131 1 3E I 44...
Page 51: ...DA70131 1 3E II 1 II I O device G9002A User s Manual...