![NPM Motionnet G9001A User Manual Download Page 120](http://html1.mh-extra.com/html/npm/motionnet-g9001a/motionnet-g9001a_user-manual_1713900120.webp)
DA70131-1/3E
VIII-2
2. Difference of electrical Characteristics
2-1. Absolute maximum ratings
There is difference as follows.
(V
SS
= 0V)
Items
Symbol
Rating
Unit
Power supply voltage
V
DD
G9002
-0.3 to +5.0
V
G9002A
-0.3 to +4.0
Input voltage
V
IN
G9002
-0.3 to V
DD
+ 0.3
V
G9002A
-0.3 to +7.0
Input voltage (5V
・
I/F)
V
IN
-0.3 to +7.0 *1
V
Output resisting
Voltage
V
ODP
-0.3 to +7.0
V
Input current
I
IN
G9002
±10
mA
G9002A
±30
Storage temperature
T
STO
G9002
-40 to +125
°C
G9002A
-65 to +150
*1
:
All Input terminals of G9002A can connect to 5V. Therefore, input voltage items are brought together
and items of input voltage (5V I/F) is deleted.
2.2 Recommended operating conditions
There is difference as follows.
(V
SS
= 0V)
Item
Symbol
Rating
Unit
MIN
TYP
MAX
Power supply voltage
V
DD
G9002
+3.0 to +3.6
V
G9002A
+3.0 to +3.6
Input voltage
V
IN
G9002
V
DD
V
G9002A
-0.3 to 5.8
Input voltage (5V
・
I/F)
V
IN
G9002
to 5.5 *1
V
Storage temperature
T
a
-40 to +85 *2
V
*1
:
All Input terminals of G9002A can connect to 5V. Therefore, input voltage items are brought together
and items of input voltage (5V I/F) is deleted.
*2 It is a recommended storage temperature based on the condition Tj=-40 to 125°C.
Summary of Contents for Motionnet G9001A
Page 1: ...DA70131 1 3E G9001A G9002A User s Manual Center device I O device Remote I O Remote Motion...
Page 7: ...DA70131 1 3E I 1 I Center device G9001A User s Manual...
Page 8: ...DA70131 1 3E I 2...
Page 50: ...DA70131 1 3E I 44...
Page 51: ...DA70131 1 3E II 1 II I O device G9002A User s Manual...
Page 52: ...DA70131 1 3E II 2...
Page 66: ...DA70131 1 3E II 16...
Page 67: ...DA70131 1 3E III 1 III Connection Examples and Recommended Environments G9000 Series...
Page 68: ...DA70131 1 3E III 2...
Page 87: ...DA70131 1 3E IV 1 IV Software Examples flow chart G9001A...
Page 88: ...DA70131 1 3E IV 2...