background image

14 

5.0 Warranty Information 

 

5.1  One Year Limited Warranty 
All Noyes Fiber Systems' products are warranted against defective material and workmanship for a period of one year from 
the date of shipment to the original customer. Any product found to be defective within the warranty period would be 
repaired or replaced by Noyes Fiber Systems. In no case will Noyes Fiber Systems' liabilities exceed the original purchase 
price of the product.

 

 

5.2  Exclusions   
The warranty on your equipment shall not apply to defects resulting from the following: 
1.  Unauthorized repair or modification. 
2.  Misuse, negligence or accident. 

 

5.3  Warranty Registration 
A warranty registration card is included with the original shipment of equipment. Please take a few moments to fill out the 
card and mail or fax it to Noyes Fiber Systems to ensure proper initiation of your warranty term. 

 

5.4  Returning Equipment 
To return equipment, please contact Noyes Fiber Systems to obtain additional information and a Return Materials 
Authorization number (RMA#). To allow us to serve you more efficiently, please include a brief description describing the 
reason(s) for the return of the equipment.

 

 

 

 

 

NOYES FIBER SYSTEMS  

 

TEL:  800-321-5298 OR 603-528-7780 

 

 

 

16 EASTGATE PARK ROAD 

 

FAX: 603-528-2025      

   BELMONT, 

NH 

 

03220 

   

Summary of Contents for SMLP 5-5

Page 1: ...User s Guide to the SMLP 5 5 Singlemode Multimode Light Pack SMLP 55 1000 Rev B 4 6 00 Provided by www AAATesters com...

Page 2: ...tions 8 3 4 Optical Reference Level 9 3 5 Optical Loss Measurement 10 3 6 Editing A Specific Memory Location 11 3 7 Verifying Output Power 12 4 0 Maintenance 13 4 1 Battery Replacement 13 4 2 Cleaning...

Page 3: ...case PC software serial cable protective rubber boots trace pads and user s guides The OLS 5 5 is a stable light source with three outputs 850 1300 and 1550 nm The OPM 5 2C is a full featured optical...

Page 4: ...sted by 1 dB 3 1550 nm Output Port and Adjustment The 1550 nm optical output is a ST connector Nominal output power is 10 dBm into 9 125 m fiber and may be adjusted by 1 dB 4 Power Switches The power...

Page 5: ...able The wavelength is displayed in the top four digits Out of range HI and LO are displayed in lower digits The OPM 5 2C will automatically detect tone at 270 Hz 1000 Hz and 2000 Hz When tone is dete...

Page 6: ...ed data is transferred to a PC using the supplied software or a serial thermal printer optionally available Hold the Store Recall keys down together until HELD displays to clear all stored data at the...

Page 7: ...to follow the precautions given below to ensure proper operation 3 1 Precautions Use care when working with any optical transmission equipment It is good practice to avoid looking directly at the outp...

Page 8: ...00 00 0200 ESCON 8800 00 0210 SC 8800 00 0209 DIN 47256 8800 00 0211 ST 8800 00 0202 FDDI Kit 8800 00 0215 E 2000 Diamond 8800 00 0221 FDDI 8800 00 0205 Biconic 8800 00 0204 D4 8800 00 0201 SMA 8800 0...

Page 9: ...expressed in dBm is the amount of optical power received by the detector as compared to 1mW 0dBm 1mW Measuring dBm is useful for verifying the output power of an optical transmitter Loss is the diffe...

Page 10: ...ing a launch jumper connect the OLS 5 5 Optical Light Source to the OPM 5 2C Optical Power Meter see Figure 3 5 Set the OPM 5 2C to dBm mode The power reading indicated by the display should be approx...

Page 11: ...5 Optical Loss Measurement Step B 1 Without removing a launch jumper from the OLS 5 5 Optical Light Source connect the OLS 5 5 and OPM 5 2C Optical Power Meter to the fiber link under test see Figure...

Page 12: ...ears to have had a problem You then take the OPM 5 2C back in the field to edit location 23 and remeasure or fix the fiber To Edit 1 Select the appropriate wavelength by pressing the key 2 Press the R...

Page 13: ...5 shows a power reading of 16 42 dBm If the manufacturer specified the output power in watts then hold the dB dBm key until HELD is displayed to change the OPM 5 2C to measure microwatts The measured...

Page 14: ...removed by using a can of filtered compressed air It is important to keep the dust cap in place when the unit is not being used OPM 5 2C Optical Power Meter The optical detector must be kept free fro...

Page 15: ...following 1 Unauthorized repair or modification 2 Misuse negligence or accident 5 3 Warranty Registration A warranty registration card is included with the original shipment of equipment Please take a...

Page 16: ...electable Power 30 hrs typical operation with 9V Alkaline Adapter Caps ST other styles available Size H x W x D 5 5 x 3 2 x 1 5 in 14 0 x 8 1 x 3 8 cm Light Source OLS 5 5 Emitter Type LED 850 1300 nm...

Page 17: ...neral Kit Specifications Dynamic Range of Test Kit Multimode 62 5 125 m Singlemode 9 125 m 40 dB 850 1300 nm 22 dB 1300 nm 50 dB 1550 nm Weight 3 3 lbs 1 5 kg Dimensions H x W x D 12 x 12 5 x 4 75 in...

Page 18: ...17 Power Port Reg 2 5 mm Tip pos 9VDC 200mA USA 9VDC 500mA Europe RS 232 Pin Designations PC CABLE DB 9 Female 3 5mm...

Page 19: ...18 Thank You for Choosing Noyes Fiber Systems 16 Eastgate Road Belmont NH 03220 Tel 800 321 5298 603 528 7780 Fax 603 528 2025 E Mail techsupp noyes fiber com Website www noyes fiber com...

Reviews: