
Users manual
Appendix A
Revision #:
A
Date:
07-14-15
Page
24
of
58
RESTART - Restart command
△
4 Format:
1
2
Num Contents
Range
Default
Remark
1
RESTART
-
-
Command Name
2
restart
mode
HOT
WARM
COLD
FACTORY
-
Restart mode
Example:
$PERDAPI,RESTART,COLD*08
Mode: cold restart
Notes:
△
4
-
As for the differences depending on the restart mode, please refer to the page of “Backup of the
Receiver Parameters (for BBRAM)”.
-
The data which is stored by FLASHBACKUP command in Flash is not cleared even if FACTORY
restart is occurred.
-
Power off/on of GT-87 corresponds to hot restart when it is within 4 hours after last fix.
-
Power off/on of GT-87 corresponds to warm restart when it is over 4 hours after last fix.
$PERDAPI , RESTART , restart mode *hh <CR> <LF>