Novus NP600 Instruction Manual Download Page 1

NOVUS AUTOMATION. 

1/3

 

 

 

NP600 

RELATIVE PRESSURE TRANSMITTER – INSTRUCTIONS MANUAL – V1.0x D 

PRESENTATION 

The 

NP600 

relative  pressure  transmitter  series  are  robust  and 

reliable  equipment  suitable  for  general  industrial  applications.  Its 
great advantage is the possibility of a fast and easy configuration of 
the operating range. With the aid of a software, the user has access 
to the most important information of the transmitter and can set the 
most appropriate configuration for the process. 

The 

NP600

  model  has  a  ceramic  sensor  with  high  mechanical 

stability.  

PRECAUTION 

Before operating the transmitter, carefully read its specifications and 
operating  instructions.  In  case  of  damage  caused  by  incorrect 
operation  or  inappropriate  usage,  and  its  consequences,  the 
guarantee becomes ineffective and null. 

A specialized professional shall perform the installation. 

A  specific  electrical  power  supply  network  should  be  provided  for 
instruments use only. 

UNPACKING 

After  unpacking  the  product,  besides  the  transmitter  it  must  be 
available: 

 

A quick guide to installation and operation. 

 

A sealed electrical connector. 

 

A screw to adjust the transmitter and the connector. 

IDENTIFICATION 

An identification label is attached to the equipment housing. On this 
label, you can found detailed information about the transmitter. 

Fig. 1

 shows the identification label with their respective information. 

 

Fig. 1

 – Transmitter identification 

 

 

 

SPECIFICATIONS 

Maximum Range (Max. Range):

 

0-2 / 0-5 / 0-10 / 0-20 / 0-50 / 0-100 Bar (*) 

Rangeability

3:1 

Measurement Accuracy: 

   ≤ 50 bar ...................................................... < ±0.5 % Max. Range 

   100 bar  ....................................................... < ±1.0 % Max. Range 

Including linearity, hysteresis and repeatability, 25 °C 

Thermal Maximum Deviation

< ±0.06 % Max. Range / °C 

Overpressure Range

Twice the value specified for the Maximum Measurement Range  

Output Signal (Output)

Electric currente, 4-20 mA, 2 wires. 

Power Supply (Power)

11 to 33 Vdc 

Electrical Connection

Connector for Type A valves (DIN EN 175301-803), IP65. 
Conductor 1.5 mm² (max.) and cables between 6 and 8 mm in 
diameter. 

Operating temperature

-20 to 70 °C 

Dinamic Response

< 30 ms 

Process Conection (Thread)

¼ NPT, ½ NPT, ½ BSP, G ¼ (*) 

Materials

Metal housing of the transmitter ...................................... Stainless 316 

Sensor (NP600) .................................................. Ceramic (Al

2

O

3

 96 %) 

Wetted parts (NP600) ............................ Sensor Ceramic (Al

2

O

3

 96 %) 

 .................................................................................. Sealing ring, FKM 

 ................................................... Metal connection, stainless steel 316 

Compatibility

:  Any  gas  or  liquid  compatible  with  the  constituent 

materials of the wetted parts. 

(*)Information available on the product identification label. 