NovoPort® IV
61
4.10.2 Menu 5 + Menu 6: Force limits for opening and closing
1.
Select menu item “5”. After approximately 2 seconds, the display flashes and
the set value for the force limit for opening appears.
2.
If desired, adjust the setting with the aid of the OPEN (B) and CLOSE (C)
buttons.
3.
Press the programming button (PROG button) (D). The display shows “6”.
After approximately 2 seconds, the display flashes and the set value for the
force limit for closure appears.
4.
If desired, adjust the setting with the aid of the OPEN (B) and CLOSE (C)
buttons.
5.
Press the programming button (PROG button) (D).
The display shows “7”.
4.10.3 Menu 7: Adjusting the light phases
1.
Select menu item “7”.
After approximately 2 seconds, the display flashes and the set value for light
time appears. The factory setting is “0”.
2.
If desired, adjust the setting with the aid of the OPEN (B) and CLOSE (C)
buttons.
3.
Press the programming button (PROG button) (D). The display shows “8”.
Crush hazard at the door!
If the force limits are set too high, there is a risk of personal injury.
The factory setting is “6” for opening and “4” for closing.
•
The force on the main closure side must not exceed 400 N /
750 ms!
Value
Light time
Warning time
24V
0
60 s
0 s
60 s
1
120 s
0 s
120 s
2
240 s
0 s
240 s
3
0 s
0 s
0 s
4
0 s
3 s
0 s
5
60 s
3 s
0 s
6
120 s
3 s
0 s
7
60 s
0 s
TAM
8
120 s
0 s
TAM
9
240 s
0 s
TAM
Remarks:
- TAM (Door open message): 24 volts if door not closed.
- If a warning time is set, the light and 24 V will switch on before the drive starts up.