Service manual
XLP 504 / XLP 506
05/2018 | 04
78
Service Electronics
OUTPUT STAGE BOARD FOR BLDC MOTOR
Notes
• BLDC = brushless direct current
• Application: XLP 50x with internal rewinder
Firmware version
• Printer firmware: at least 3.34
• Firmware output stage driver: at least 6
Checking the firmware version
Call
Info > Status Printouts > Service Status
.
Section „Peripheraldriver“ on the printout lists all mounted output stage boards with the installed
firmware versions.
Updating firmware
Updating the driver firmware is done the same way as with the printer firmware:
See chapter
The following files are required:
BLDC_Vx.BAT
resp.
BLDCAP54Vx.S3B
(for firmware version x).
CAUTION! - Don´t load the older firmware version 1 onto the new version 2!
Connections, settings
[116] Connections on the BLDC output stage board (A4034).
A
Connection D-Sub cable harness, sensor of the peripheral device (CN101)
Only used in XLP 50x „basic dispenser“!
A
B
C
D
E