Service manual
XLP 504 / XLP 506
05/2018 | 09
135
Only if
Options > Selection > Periph. device
= „Dispenser“ oder „Intern. rewinder“
Sets the brake current.
Break diameter
Only visible in service mode
Only if
Options > Selection > Periph. device
= „Dispenser“ oder „Intern. rewinder“
Sets the break diameter.
Keyboard
Setting the keyboard layout country version for standalone operation.
External signal
The parameter determines, if and how an incoming signal at the - optional - single start connector
will be interpreted.
•
Off
: Signal interpretation disabled.
•
Singlestart
: The signal triggers the printing of a single label. This setting may be used e.g. for
printing single labels by means of a foot switch.
•
Stacker full
: The signal triggers the display of a status report and stops the printer. This setting
may be used when using a stacker (= stacker full signal).
Language
Setting the display language.
Setting range
Default setting
Step width
Easy Plug
[0...120]
120
1
#PC2511
Settings
Default setting
Step width
Easy Plug
German, English, French, Spa-
nish, Danish, Finnish, Swedish,
Polish,
English
--
#PC2063
Settings
Default setting
Step width
Easy Plug
Off, Singlestart, Stacker
fail
Off
--
#PC2042
Settings
Default setting
Step width
Easy Plug
German, English, French, Spa-
nish, Dutch, Danish, Italian, Po-
lish, Turkish, Russian, Czech,
Chinese
a
, Japanese
a) Not all display texts are translated. Not translated texts are displayed in english.
English
--