04/16 Rev. 06
USER MANUAL
Advanced Applications
AP 4.4 – AP 5.4 – AP 5.6 – AP 7.t – 64-xx – DPM – PEM – ALX 92x
19
Setting the IP Parameters
The IP-parameter settings can either be set fix, or they can be requested from a DHCP
server with every start of the printer. To assist the system administrator, the DHCP
server is provided a device name on request, which consists of a combination of print-
er type + 3 digits from the MAC address. (e.g. AP_5.4___300dpi_020049). The follow-
ing values have been preset:
• IP address: 192.168.1.99
• Net mask: 255.255.255.0
• Default gateway: 0.0.0.0
Connection to a name server is not required.
WARNING: The address allocation for each device must be clear and unambigu-
ous. Ask your network administrator for assistance!
Transmission with Raw Socket Interface
Printing data can be transmitted using a parameterisable socket interface (TCP server
socket on port number > 1024).
This protocol is supported by
• all Unix derivatives; a connection similar to that of terminal servers can be estab-
lished.
• Windows 2000, Windows XP
In this way you can set the Port address in the printer’s parameter menu:
Menu
Parameter
Description
INTERF. PARAM. >
NETWORK PARAM
IP addressassign
Here, please set “fixed IP address” or “DH-
CP”.
IP address
Net mask
Gateway address
IP parameter input fields, in case “fixed IP
address” was set for the address assign ty-
pe.
[Tab. 18] Setting the IP parameters in the printer menu
Parameter
Description
INTERF. PARAM. > NETWORK PARAM. > Port
address
Here you can select the port number
of the service in section 1024-65535
INTERF. PARAM. > EASYPLUGINTERPR > In-
terface
Here a TCP/IP socket must be set in
order to receive printing data at the
set port number.
[Tab. 19] Setting the port address in the printer´s parameter menu
Summary of Contents for ALX 92x
Page 3: ...Release 3 6 2016 SERVICE MANUAL ALX 92x Print Apply system ...
Page 356: ...12 14 Rev 05 SERVICE MANUAL Service Electronics 64 xx Gen 2 DPM Gen 2 ALX 92x Gen 2 43 ...
Page 508: ...Edition 1 3 2016 INSTALLATION MANUAL AI retrofitting kit for ALX 92x ...
Page 509: ......
Page 511: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 4 Content ...
Page 520: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 00 13 Installation ...
Page 521: ......
Page 522: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...