04/16 Rev. 06
USER MANUAL
Advanced Applications
AP 4.4 – AP 5.4 – AP 5.6 – AP 7.t – 64-xx – DPM – PEM – ALX 92x
14
Insert Input Field in Printjob
Input fields can be defined in the following Easy Plug field types:
• Text field
• Counting field
• Barcode field
These field types can be defined through the following Easy Plug commands: YT, YN,
YB, IDM, PDF, MXC, CBF, YC, YS, YG.
Using a special syntax it is made clear in these commands that the text dealt with here
is not a fixed text, but text requested at the time of implementation.
Further information on the input field syntax can be found in the description of the re-
spective command in the Easy Plug Manual, topic section
.
Example Application
1. Generate two text files with the content shown in the tables below.
Tip: Cut out the content using the Acrobat Reader text selection tool and copy
it to a text file.
2. Create a directory on the memory card called
\FORMATS
.
3. Store the two text files as
TEST1.FOR
and
NOVEXX.FOR
on the memory card in
the directory
\FORMATS
.
The file ending must be
*.FOR
!
There is no difference made between uppercase and lowercase letters!
4. Switch off printer.
5. Insert memory card into the printer’s card slot.
6. Turn on printer and switch to online mode.
Example
#!A1#IMN100/60#ER
#J40#T5#YT107/0///Simple test for
#J30#T5#YN100/0/60///STANDALONE Mode
#Q3/
[Tab. 14] File „TEST1.FOR“
Example
#J10#T5#YT107/0///Fixtext#G
#J40#T5#YN100/0/60///$<Color:>,Lightred
#J40#T5#YN100/0/60///$<Color:>,Lightred
#J20#T5#YT107/0///$<Article number:>,
#!A1#IMN100/60#ER
#Q3/
[Tab. 15] File „NOVEXX.FOR“
Summary of Contents for ALX 92x
Page 3: ...Release 3 6 2016 SERVICE MANUAL ALX 92x Print Apply system ...
Page 356: ...12 14 Rev 05 SERVICE MANUAL Service Electronics 64 xx Gen 2 DPM Gen 2 ALX 92x Gen 2 43 ...
Page 508: ...Edition 1 3 2016 INSTALLATION MANUAL AI retrofitting kit for ALX 92x ...
Page 509: ......
Page 511: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 4 Content ...
Page 520: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 00 13 Installation ...
Page 521: ......
Page 522: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...