04/16 Rev. 11
USER + SERVICE MANUAL
/Status Reports
64-xx – DPM – PEM – ALX 73x (PMA) – LPA 81x (Printer) – ALX 92x – AP 5.4 – AP 5.6
54
5201 Touch
down
Status
The applicator did not reach its touch down position within the given time
frame.
Measure
Check cable and compressed air connections; reconnect them properly, if
necessary.
May the applicator move unhindered? – remove any obstacles.
5203
Touch down sens.
Status
The touchdown sensor(s) was/were already triggered before the
application.
Measure
Check cable and compressed air connections; reconnect them properly, if
necessary.
5204 Appl.
Starterror
Status
The device received another start signal during printing/applying a label.
Precondition: Parameter
APPLICATOR PARA > Start error stop
or
DP INTERFACE > Start error stop
is set to
On
.
Measure
Check the labelling procedure; increase the product distance.
Set parameter
Start error stop
to
Off
.
5205 Applicator
gen.
Status
General software error
Measure
Please read the notes in section
.
5206 Applicator
resp.
Status
Communication with the AI exceeded a given time frame.
Measure
Switch the printer off and on again after half a minute. If the error still
occurs after several trys, please contact our technical support.
5207
Appl. driver 1
Status
Shortcut or overheat at power output 1 at the applicator connector (CN603)
on the AI board. The power output 1 comprises the following output signals:
•
Cylinder
•
Vacuum
•
Airstream Support
•
Blow On
Measure
Check the connections.
Summary of Contents for ALX 92x
Page 3: ...Release 3 6 2016 SERVICE MANUAL ALX 92x Print Apply system ...
Page 356: ...12 14 Rev 05 SERVICE MANUAL Service Electronics 64 xx Gen 2 DPM Gen 2 ALX 92x Gen 2 43 ...
Page 508: ...Edition 1 3 2016 INSTALLATION MANUAL AI retrofitting kit for ALX 92x ...
Page 509: ......
Page 511: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 4 Content ...
Page 520: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 00 13 Installation ...
Page 521: ......
Page 522: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...