04/16 Rev. 11
USER + SERVICE MANUAL
/Status Reports
64-xx – DPM – PEM – ALX 73x (PMA) – LPA 81x (Printer) – ALX 92x – AP 5.4 – AP 5.6
43
Measure
Switch printer off and then back on again after 30 sec. If the error message
continues to appear, please contact the manufacturer.
5026 Motorprotect
CPU
Status
(AP x.x only) The motor driver board (output stage board) is overheated or
defective.
Measure
Switch printer off and then back on again after 30 sec.
If the error message continues to appear:
Replace the motordriver board.
5028 PS
overheat
(AP x.x only)
Status
The temperature inside of the power supply exceeded the admissible
range.
Measure
Let the power suppy cool down for some minutes.
5029
I2C checksum xx
Status
During
I
2
C communication with device xx occured a checksum error.
xx = I
2
C device number (see Tab. 4 on page 37).
Measure
Switch printer off and then back on again after 30 sec. If the error message
continues to appear, please contact the manufacturer.