04/16 Rev. 11
USER + SERVICE MANUAL
/Status Reports
64-xx – DPM – PEM – ALX 73x (PMA) – LPA 81x (Printer) – ALX 92x – AP 5.4 – AP 5.6
34
2500 Multiple
texts
Status
This status number may be combined with variety of texts, which all are
generated by the Basic interpreter. The Basic interpreter is a function which
is not realeased nor supported.
Measure
Switch off the Basic interpreter (
SYSTEM PARAMETERS > Print Interpret.
).
3000/3003/3006/3012/3015
Com x Overrun
Status
Receive error at the RS232 interface
COMx
(x = [1…5]).
Measure
Acknowledge by pressing the Online button.
3001/3004/3007/3013/3016
Com x Parity
Status
Receive error at the RS232 interface
COMx
(x = [1…5]).
Measure
Acknowledge by pressing the Online button.
Check parameter setting at printer (
INTERF. PARAM. > COM1 PORT > Parity
) and
PC.
Notes about setting the printer parameters are given in the chapter "Info
Print-outs and Parameters" in the User Manual.
3002/3005/3008/3015/3017
Com x Frame
Status
Receive error at the RS232 interface
COMx
(x = [1…5]).
Measure
Acknowledge by pressing the Online button.
Check parameter setting at printer (
INTERF. PARAM. > COM1 PORT > Baud rate
and
INTERF. PARAM. > COM1 PORT > stop bits
) and PC.
Notes about setting the printer parameters are given in the chapter "Info
Print-outs and Parameters" in the User Manual.
3010 Spooler
Overflow
Status
Fault which is caused by a faulty handshake at an interface. The
consequence is an overflowing data buffer at the printer, because the host
doesn´t stop to send data to the printer.
Measure
Acknowledge by pressing the Online button.
Check the connections of the data line, especially the signal wires
belonging to the handshake.
Check the interface settings, especially the handshake settings.
3011
Send buffer full
Status
The send buffer is full. This error may happen, if the printer status was
requested several times (#!Xn), but the status reply was not read out.
Measure
Make sure that the status reply is read out.
Summary of Contents for ALX 92x
Page 3: ...Release 3 6 2016 SERVICE MANUAL ALX 92x Print Apply system ...
Page 356: ...12 14 Rev 05 SERVICE MANUAL Service Electronics 64 xx Gen 2 DPM Gen 2 ALX 92x Gen 2 43 ...
Page 508: ...Edition 1 3 2016 INSTALLATION MANUAL AI retrofitting kit for ALX 92x ...
Page 509: ......
Page 511: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 4 Content ...
Page 520: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 00 13 Installation ...
Page 521: ......
Page 522: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...