05/16 Rev. 03
USER- / SERVICE MANUAL
Info-Printouts & Parameters
AP 5.4 Gen II – AP 5.6
AP 4.4 – AP 5.4
64-xx – DPM – PEM – ALX 92x – ALX 73x (PMA)
117
Sets the delay time, after which a position error of the applicator is displayed
as an error. A position error occurs, if the applicator doesn´t reach any of its
end positions within the required time frame.
xxxxx ms
Setting range: 200 to 99999 ms; Unit interval: 1 ms;
Default setting: 2000 ms
Off
Set x<500 to disable the function.
Lab release time
ALX 92x
DPM
Only with an AI installed.
Not
with
APPLICATOR PARA > Applicator type
= „ASA“.
Required setting:
APPLICATOR PARA > Application mode
= „After printing“
Defines a delay between the dispensing and the start of application of the la-
bel.
xxxx ms
Setting range: 1-99999 ms; Unit interval: 1 ms; Default setting: 0 ms
Touch down sens.
ALX 92x
DPM
Switching behaviour of the touchdown sensor.
Only with an AI installed.
Only visible with certain applicator types.
Pulse falling
The
falling
signal edge at the sensor triggers the touchdown trigger event
Pulse rising
The
rising
signal edge at the sensor triggers the touchdown trigger event
TouchDownTimeout
ALX 92x
DPM
Timeout at the touchdown sensor.
Only with an AI installed.
Only visible with certain applicator types.
This time specifies the maximal wait time for the touchdown trigger event.
If the specified time is exceeded without the touchdown event, the appli-
cator continues operation in the same manner as the touchdown event
would have taken place.
No
error message will appear in this case.
xxxxx
Setting range: 100 to 99999 ms
Off
(Default setting)
Summary of Contents for ALX 92x
Page 3: ...Release 3 6 2016 SERVICE MANUAL ALX 92x Print Apply system ...
Page 356: ...12 14 Rev 05 SERVICE MANUAL Service Electronics 64 xx Gen 2 DPM Gen 2 ALX 92x Gen 2 43 ...
Page 508: ...Edition 1 3 2016 INSTALLATION MANUAL AI retrofitting kit for ALX 92x ...
Page 509: ......
Page 511: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 4 Content ...
Page 520: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 00 13 Installation ...
Page 521: ......
Page 522: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...