05/16 Rev. 03
USER- / SERVICE MANUAL
Info-Printouts & Parameters
AP 5.4 Gen II – AP 5.6
AP 4.4 – AP 5.4
64-xx – DPM – PEM – ALX 92x – ALX 73x (PMA)
116
Level high active
Labels will be printed as long as the start signal is held high.
Pulse rising
The printing of a label is triggered by a low-high change of the start signal.
The printing occurs only after the set delay time.
Level low active
Labels will be printed as long as the start signal is held low.
Pulse falling
(Default setting) The printing of a label is triggered by a high-to-low change
of the start signal. The printing occurs only after the set delay time.
Dwell time
ALX 92x
DPM
Only with an AI installed.
Only if
APPLICATOR PARA > Applicator type
= „PEP“, „PEP Blow on“, „Reverse
PEP“, „BTS“, „LA-SO“, „LA-TO zeitgest.“.
Defines the dwell time for the apply cylinder. The dwell time is the time during
which the cylinder valve is turned on.
xxxxx ms
Setting range: 1 to 99999 ms; Unit interval: 1 ms; Default setting: 1 ms
Blow on time
ALX 92x
DPM
Only with an AI installed.
Only if
APPLICATOR PARA > Applicator type
= „PEP Blow on“, „PEP II Sensor“,
„ASA“, „Reverse PEP“, BTS, „O-Ring Applikator“, „
LTP - LTPV“
or „LA-BO“.
Standard applicators of the LTP/LTPV types don´t need the „Blow on
time“ signal, therefore this parameter is not relevant for them. The pa-
rameter is intended for special variants of the LTP/LTPV applicator, which
provide an additional blow-on function using this signal.
xxxxx ms
Setting range: 0 to 99999 ms; Unit interval: 1 ms; Default setting: 1 ms
Restart delay
ALX 92x
DPM
Only with an AI installed.
Sets the delay time after the application, during which no start signals are
accepted.
xxxxx ms
Setting range: 0 to 99999 ms; Unit interval: 1 ms; Default setting: 0 ms
Position timeout
ALX 92x
DPM
Only with an AI installed.
Not
with
APPLICATOR PARA > Applicator type
= „ASA“, „Direkt Spenden“,
„LA-BO“.
Summary of Contents for ALX 92x
Page 3: ...Release 3 6 2016 SERVICE MANUAL ALX 92x Print Apply system ...
Page 356: ...12 14 Rev 05 SERVICE MANUAL Service Electronics 64 xx Gen 2 DPM Gen 2 ALX 92x Gen 2 43 ...
Page 508: ...Edition 1 3 2016 INSTALLATION MANUAL AI retrofitting kit for ALX 92x ...
Page 509: ......
Page 511: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 4 Content ...
Page 520: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 00 13 Installation ...
Page 521: ......
Page 522: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...