05/16 Rev. 03
USER- / SERVICE MANUAL
Info-Printouts & Parameters
AP 5.4 Gen II – AP 5.6
AP 4.4 – AP 5.4
64-xx – DPM – PEM – ALX 92x – ALX 73x (PMA)
92
Detailed information about using start signals can be found in the user man-
ual, topic section „Advanced Applications“, chapter „Printing with start sig-
nal“,
Settings in the parameter menu
Only appears here, when
no
I/O board is installed. Otherwise, this
parameter appears in the
I/O BOARD
menu.
For details see paragraph Start print mode
Start print mode
64-xx
ALX 92x
DPM
PEM
AP 4.4
AP 5.4
Selecting a print mode. Depending on the selected mode, a start signal at the
single-start input will be interpreted differently.
Information about using the start signal: see user manual, topic section „Spe-
cial applications“, chapter „Printing with start signal“.
Pulse fall/ris
The printing of a label is triggered by a low-high-change as well as by a high-
low-change of the start signal. The printing occurs only after the set delay
time.
Level high activ
Labels are being printed as long as the start signal is held high.
Pulse rising
The printing of a label is triggered by a low-high-change of the start signal.
The printing occurs only after the set delay time.
Level low active
Labels are being printed as long as the start signal is held low.
Pulse falling
(Default setting)
The printing of a label is triggered by a high-low-change of
the start signal. The printing occurs only after the set delay time.
Apply key
64-xx
ALX 92x
DPM
PEM
64-xx: Only if
SYSTEM PARAMETER > Periph. device
is set to „Dispenser“.
Parameter is displayed in production mode only.
Only if
SYSTEM PARAMETER > External signal
is set to „Singlestart“
On
(Default) The application can be triggered by pressing the cut respectively
apply key.
Off
Triggering the application by pressing the cut/apply key is
not
possible.
Print contrast
64-xx
ALX 92x
DPM
PEM
ALX 73x (PMA)
AP 4.4
AP 5.4
AP 5.6
xxx%
Setting range: 1 to
110
120
%; Unit interval: 1; Default setting: 60
Summary of Contents for ALX 92x
Page 3: ...Release 3 6 2016 SERVICE MANUAL ALX 92x Print Apply system ...
Page 356: ...12 14 Rev 05 SERVICE MANUAL Service Electronics 64 xx Gen 2 DPM Gen 2 ALX 92x Gen 2 43 ...
Page 508: ...Edition 1 3 2016 INSTALLATION MANUAL AI retrofitting kit for ALX 92x ...
Page 509: ......
Page 511: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 4 Content ...
Page 520: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 00 13 Installation ...
Page 521: ......
Page 522: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...