05/16 Rev. 03
USER- / SERVICE MANUAL
Info-Printouts & Parameters
AP 5.4 Gen II – AP 5.6
AP 4.4 – AP 5.4
64-xx – DPM – PEM – ALX 92x – ALX 73x (PMA)
91
Tear-off edge
Sets the printer firmware to the tear-off edge option. The punch is fed forward
to the tear-off edge.
Dispenser
Setting for
64-xx
AP 5.4
/5.6
dispenser version.
64-04/05 only: After selecting this value, the parameter
SPECIAL FUNCTION >
Disp. Head Offs.
appears automatically, if the parameter
SPECIAL FUNCTION >
Printhead type
is set to „KCE 4 Inch“.
See parameter Disp. Head Offs.
Intern Rewinder
AP 5.4/5.6 dispenser only: Setting for printer operation in „internal rewinder“
mode, that is operation with a deflector and without dispensing edge.
Tear-off + sensor
AP 5.4 only: Setting for using the dispensing edge as tear-off edge. The
punch is fed forward to the dispensing edge.
TCS
AP 7.t only: Textile Cutter-Stacker
Disp. with LTSI
Setting for operation of a LTSI applicator, see Technical Manual LTSI
Singlestartquant
64-xx
ALX 92x
DPM
PEM
AP 4.4
AP 5.4
AP 5.6
Determines the label quantity, which will be printed after a start signal.
xx
Setting range: 1 to 10; Unit interval: 1; Default setting: 1
Head disp dist
(Distance printhead - dispensing edge)
64-xx
ALX 92x
DPM
64-xx: 64-xx dispenser only and only with
SYSTEM PARAMETER >
Dispensing edge = „User defined“
For setting the distance between printhead and dispensing edge.
xxx.x mm
Setting range: 10.0 to 100.0 mm; Unit interval: 0.1 mm; Default setting: 20
mm
External signal
64-xx
ALX 92x
DPM
PEM
AP 4.4
AP 5.4
AP 5.6
The parameter determines, if and how an incoming signal at the - optional -
single start connector will be interpreted.
Off
Signal interpretation disabled.
Singlestart
The signal triggers the printing of a single label. This setting may be used e.g.
for printing single labels by means of a foot switch.
Stacker full
The signal triggers the display of a status report and stops the printer. This
setting may be used when using a stacker (= stacker full signal).
Summary of Contents for ALX 92x
Page 3: ...Release 3 6 2016 SERVICE MANUAL ALX 92x Print Apply system ...
Page 356: ...12 14 Rev 05 SERVICE MANUAL Service Electronics 64 xx Gen 2 DPM Gen 2 ALX 92x Gen 2 43 ...
Page 508: ...Edition 1 3 2016 INSTALLATION MANUAL AI retrofitting kit for ALX 92x ...
Page 509: ......
Page 511: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 4 Content ...
Page 520: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 00 13 Installation ...
Page 521: ......
Page 522: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...