05/16 Rev. 06
SERVICE MANUAL
Applicator Interface
ALX 92x – ALX 73x
Signal-Time-Diagrams
7
PEP IV / LA-TO timed / LA-SO
[1] Pattern of control signals over time for PEP IV, LA-TO timed and LA-SO applicators.
A
Duration is determined by label length and dispensing speed. „Airstream Support“ switching to low
means the label is dispensed.
B
Can be adjusted via
APPLICATOR PARA > Dwell time
. Duration t is determined by the backwards move-
ment of the applicator. The application cycle ends when the home position signal is high again.
C
The output signal „Offline“ follows the input signal „Inhibit“.
D
The start signal is ignored because of the active „Inhibit“.
A
B
C
D