07/15 Rev. 02
SERVICE-HANDBUCH
Reading out diagnosis data
DPM – PEM – ALX 92x
9
Storing on memory card
Prerequisites
• Firmware (at least):
• Memory card plugged into the card slot.
Carrying out
1. Call
SPECIAL FUNCTION > Store diagnosis
.
Display:
The second line shows the initial 16 characters of
the default file name. The complete file is named:
Diagnose ALX 924 A662106113006132.log
with:
–
ALX 924
: Machine type, machine version (RH/
LH, only displayed if RH)
–
A662106113006132
: Serial number of the CPU
board; equals the string in
SERVICE DATA >
CPU BOARD DATA > Serial number
2. Press the ONLINE button twice to acknowledge
and to store the file name.
Typing in a new file name:
1. Press the PROG button to dismiss the default file
name.
2. Select each character of the new file name by pres-
sing the FEED/APPLY buttons and acknowledge it
by pressing the ONLINE button.
3. Finally press the ONLINE button twice to ack-
nowledge and store the file.
Alternatively, type in the file name on an optional
keyboard connected to the printer and acknowledge by
pressing online.
The log file will be stored in the \LOGFILES directory on
memory card.
Hardware
Firmware
Electronics Gen. 2
4.31
Electronics Gen. 3
5.31
Store Diagnosis
Diagnosis ALX 924
Summary of Contents for ALX 92x
Page 3: ...Release 3 6 2016 SERVICE MANUAL ALX 92x Print Apply system ...
Page 356: ...12 14 Rev 05 SERVICE MANUAL Service Electronics 64 xx Gen 2 DPM Gen 2 ALX 92x Gen 2 43 ...
Page 508: ...Edition 1 3 2016 INSTALLATION MANUAL AI retrofitting kit for ALX 92x ...
Page 509: ......
Page 511: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 4 Content ...
Page 520: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 00 13 Installation ...
Page 521: ......
Page 522: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...