Service Manual
ALS/XLS 20x/256/272
02/2019 | 01
210
1) I
max
over all outputs < 1500 mA
Signal response „Dispense End“
[162] Signal response of „Dispense End“.
The signal „Dispense End“ can be controlled by the functions in the
SIGNAL INTERFACE >PLC SIGNALS
submenu.
A
Duration of the dispensing operation [162A]
B
Period setable via
SIGNAL INTERFACE >PLC SIGNALS > Disp.end delay
C
Period setable via
SIGNAL INTERFACE >PLC SIGNALS > End pulse width
D
Signal modes; setable via
SIGNAL INTERFACE >PLC SIGNALS > End dispense mod
– Modes
high/low active
: The signal is activated with the start of dispensing. The duration is the
sum of the three periods A+B+C.
– Modes
high/low pulse
: The signal is activated after dispensing ended and after period B and it
lasts period C [162C].
Error
Output
Signal active when an error message appears on the operator panel display
I
out
< 500 mA
1)
Dispense End
Output
Signal that can be used to activate a secondary unit (e.g. a printing unit). Signal
length and delay can be set via the function menu
I
out
< 500 mA
1)
Warning
Output
Active, if a warning status occurs (e. g. label roll diameter below desired nominal
value)
I
out
< 500 mA
1)
Signal name
Function
dispense
high active
low active
high pulse
low pulse
D
B C
A
Summary of Contents for ALS/XLS 204
Page 2: ......
Page 8: ...Service Manual ALS 20x 256 272 05 2019 8 Contents ...
Page 110: ...Service Manual ALS XLS 20x 256 272 02 2019 02 110 ...
Page 258: ...Service Manual ALS XLS 20x 256 272 02 2019 03 258 Repair 199 Removing the fan C A B C D ...
Page 309: ......
Page 310: ......
Page 311: ......
Page 312: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...