![Novatel SMART7 Installation And Operation User Manual Download Page 140](http://html.mh-extra.com/html/novatel/smart7/smart7_installation-and-operation-user-manual_1711399140.webp)
APPENDIX A SMART7 Technical Specifications
SMART7 Installation and Operation User Manual v6
140
A.5 SMART7 Strobe Specifications
The SMART7 strobe signals are available on the 14-Pin Interface connector. Pulse Per Second (PPS) strobes
provide synchronization signal.
Refer to
SMART Antenna Interface Cable (Optional Accessory)
on the next page for pin out details.
Strobes
Input/Output
Comment
Emulated
Radar (ER)
Output
0VDC to VBATT+
Use the
RADARCONFIG
command to configure ER.
Emulated Radar pulses are output through the
on the next page and the
RADARSTATUS
log.
PPS
Output
3.3V CMOS
A time synchronization output. This is a pulse where the leading edge is
synchronized to receiver calculated GNSS Time. The polarity, period and pulse
width can be configured using the
PPSCONTROL
command.
Table 27: SMART7 Strobes Description