APPENDIX A IMU Technical Specifications
OEM7 SPAN Installation and Operation User Manual v14
262
A.19.3 MIC Connectors
Connector
Description
Part Number
Mating Connector
Part number
J301
20-pin OEM719 mating connector
ASP-163577-
01
SAMTEC
Connects only to OEM719
receiver.
P101
3-pin locking power connector
43650-0313
Molex
Electronics
43645-0300
Molex Electronics
P301
30-pin locking communication connector
501571-3007
Molex
Electronics
501189-3010
Molex Electronics
P601
20-pin locking IMU connector for Honeywell and
Sensonor IMUs
53780-2070
Molex
Electronics
51146-2000
Molex Electronics
P701
10-pin locking IMU connector for ADIS IMUs
53780-1070
Molex
Electronics
51146-1000
Molex Electronics
Table 149: MIC Connectors
Pin
Signal
Type
Description
Comments
1
VIN+
Power
Power input
+10 VDC to +30 VDC
2
VIN-
Power
Power return
Connect to negative terminal of battery
3
GND
Power
Chassis ground
Table 150: Pinouts for Power Connector (P101)
Pin
Signal
Type
Description
Comments
1
N/C
2
N/C
3
LED3
Output
Status LED 3 /
Self-test
4
LED2
Output
Status LED 2 /
GPS Time Status
5
DGND
Power
Digital ground
Table 151: Pinouts for User Interface Connector (P301)