Data Logs
Chapter 6
EuroPak-15a Receiver User Manual Rev 5
101
Table 50: Version Log Field Formats
Field Name
Field Format
Description
hw version
P-RS-CCC
P= hardware platform (e.g. OEM4)
R = hardware revision (e.g.3.10)
S = processor revision (e.g. A)
CCC = COM port configuration (e.g. 22T)
a
a. One character for each of the COM ports 1, 2, and 3. Characters are: 2 for RS-232, 4 for RS-422, and
T for LV-TTL. Therefore, the example is for a receiver that uses RS-232 for COM 1 and COM 2 and LV-
TTL for COM 3.
sw version, boot version
VV.RRR[Xxxx]
VV = major revision number
RRR = minor revision number
X = Special (S), Beta (B),
Internal Development (D, A)
xxx = number
comp date
YYYY/MM/DD
YYYY = year
MM= month
DD = day (1 - 31)
comp time
HH:MM:SS
HH = hour
MM = minutes
SS = seconds