![Novatel DL User Manual Download Page 62](http://html.mh-extra.com/html/novatel/dl/dl_user-manual_1711293062.webp)
Appendix E – DL Commands
62
DL™ User Manual Rev 3
Examples:
site add hilltop 4
site add SW_corner_of_fence 143 1.402 tape_measure
Syntax 3:
Specific site information can be entered or updated using this command. You can enter 1 to 4 of the optional fields in any
order, provided that the syntax is observed. If no value is specified after the ‘=’ sign of a field, its value is cleared, that is,
a default value is assigned to it.
SITE UPDATE [number=site number] [name=site name]
[ameasure=mcode] [attrib=attribute]
Command
Option
Description
Default
SITE UPDATE
-
Command
number=
Enter a site number (up to 8 alphanumeric characters, no spaces) to
identify a set of collected data.
name=
Enter a descriptive name (up to 32 alphanumeric characters, no spaces)
to define the site where data collection occurs.
aheight=
Enter the antenna’s height, in meters.
ameasure=
Enter a code (up to 16 alphanumeric characters, no spaces) that
describes how the antenna’s height was determined.
attrib=
Enter an integer code (an integer up to 4 digits long, of your choosing)
that describes this type of site.
Examples:
site update name=bridge
site update aheight=1.52 name=NE_corner_of_pier attrib=2
site update ameasure=502-TRUE number=7ABCD8 aheight=1.203 name=statue
SLEEP
This command allows you to enable or disable the power-saving mode. SLEEP, entered with no arguments, causes the
DL to disable manual logging (if active), then enter low-power mode and wait for scheduled events. If a logging event is
scheduled to start within a short amount of time, the DL will not enter low-power mode.
Syntax:
SLEEP
[keyword]
Command
Option
Description
SLEEP -
Command
keyword
OFF
Disable the low-power mode and cause the DL to stay fully powered between
scheduled events.
Examples:
sleep
sleep off
Summary of Contents for DL