NWB-DC IM 3 JAN 2014
© 2014 Novatec, Inc. All Rights Reserved
Page 9
NWB-DC IM 3 JAN 2014
Hopper Receivers with Blowback
are supplied with a male/female twist lock plug to which 115/1/50-60 VAC
should be wired. A clean source of 80-120 psi compressed air should be connected to the supplied FNPT fitting.
(3/8” on the VR-5 and ¼” on the VR-12)
3.3 Positioning the NWB-DC
Roll the NWB-DC into position next to the process machine it will be serving.
NOTE: LOCATION
Position your NWB-DC Series dryer in a location where material and vacuum hoses will not be
disturbed. Allow sufficient distance (at least 2 feet) from the surrounding equipment, so the access
doors may be opened to perform routine maintenance on the dryer and for safe operation.
3.4 Install Machine Mount Receiver and Connect Flex Hose
3-A
: Bolt the Machine Mount Receiver to the process machine throat with user-supplied bolts.
3-B
: Push one end of the flex hose all the way onto the material inlet stub on the side of the receiver and
fasten it securely with a hose clamp (supplied).
3-C
: String flex hose to the vacuum purge take-off (attached to the bottom of the hopper) cut it to length
and fasten securely with a hose clamp.
3-D
: Attach one end of flex hose to the vacuum inlet stub on top of the Machine Mount receiver and
fasten it securely with a hose clamp.
String the flex hose to the farthest EPV Dual Station
Vacuum Valve Stub extending from the top of the dryer.
Cut flex hose to length and attach it
securely to the stub with a hose clamp.
3-A
3-B
3-C
3-D
3-D
Entry point for power