LED Display Controller Thunderview_S1
User Manual
6 Operations
www.novastar.tech
9
6.3.2 Advanced Configuration
The
Advanced Config
function can be enabled when
Large Load
in loading modes
is selected.
After enabling
Advanced Config
, set the
Cabinet Row QTY
,
Cabinet Col QTY
,
Start X
and
Start Y
(image offset), and
Data Flow (Front View)
for
Out1 Setting
(Output1) and
Out2 Setting
(Output 2) respectively.
6.3.3 Image Offset
Set
Start X
and
Start Y
(the horizontal and vertical offsets of the image).
6.4 Input Settings
The user can set resolutions for input sources based on actual needs.
Setting Methods
Method 1: Set the
Preset
resolution.
Select a proper resolution from the resolution presets and press the knob to save
the setting.
Method 2: Set a
Custom
resolution.
After choosing
Custom
, set
Width (H)
,
Height (V)
and
Refresh Rate
. Then,
select
Apply
and press the knob to save the settings.
XI'AN
NOVASTAR
TECH
CO.,
LTD.