PRECESSION ELEPHANT 2 Scan Head 2
Installation examples
Not available
13.10.4 DC INPUT
, no.
⑥
Purpose
The scan head is supplied with voltage via this interface.
Further reading
None
Implementation
Connector name:
DC INPUT
Connector type:
3W3 D-sub connector, 3F3CS, keyed
Maximum wire length: depending on cable cross section,
standard lengths 5 m and 10 m, or customer specific
Characteristics:
none
Table 26: Pin assignment of the DC INPUT connector
DC INPUT
Pin Signal name Type
1
U +
VI
2
GND
-
3
U
–
VI
Signal name
U+
positive and negative voltage respectively, 24 V,
U
–
a voltage between 13.5 and 28 V is allowed;
standby consumption per scan head axis 7 W (typically);
load per scan head axis max. 2 A;
recommended fuse T 3.15 A each
GND ground
98