INPUT/OUTPUT SIGNALS
PAGE
|
69
A Programmable Logic Controller (PLC) can also drive F201 laser inputs. Figure below shows a typical
method for connecting to a PLC output module when only one F201 laser input is used.
Figure 4-10 PLC driven interlock signal.
When multiple PLC outputs are used, connect F201 laser inputs to the PLC as shown in Figure below. By
supplying voltage (+VDC) to Pin 11, Input Common, and pulling individual inputs to ground, each input can
be independently activated by the PLC’s output module.
Figure 4-11 Multiple PLC driven inputs.
Summary of Contents for f201
Page 1: ...ENGINEERED BY SYNRAD f201 Laser User Manual...
Page 15: ...INVENTORY PAGE 15 Inventory F201 Lasers Figure 2 3 f201 shipping box contents...
Page 36: ...F201 LABEL LOCATIONS PAGE 36 f201 label locations Figure 3 1 100 hazard label locations...
Page 44: ...COMPLIANCE PAGE 44 Figure 3 4 f201 Declaration Document...
Page 45: ...COMPLIANCE PAGE 45 Figure 3 5 continued F201 Declaration Document...
Page 76: ...INTEGRATING F201 SAFETY FEATURES PAGE 76 Figure 4 15 F201 packaging diagram...
Page 78: ...F201 GENERAL SPECIFICATIONS PAGE 78 Table 4 9 f201 general specifications continued...