Calculate the length of the Optira tape scale required for your application using the
following formula:
ML + 10 mm = Length of Tape Scale
ML = Measuring Length (refer to the encoder interface drawing)
11.1.5 Prepare Mount
i
ng Surface
Perform the following steps prior to tape scale installation.
Step
Action
7. Inspect the mounting surface for any machining irregularities. MicroE Systems recommends
a surface finish of better than 3.2 micrometers Ra.
8. Thoroughly clean the scale mounting surface and reference edge using a cotton swab or
lint-free cloth dampened with isopropyl alcohol or acetone. Remove all dust and particles.
9. Mark the starting location on the mounting surface where the tape scale will be applied to
ensure accurate positioning of the scale. The tape scale is designed for one time installation
only and not for re-application due to misplacement.